1:32 PLC splitter Planar lightwave circuit Rack Mount
USD $45 - $55 /Piece
Min.Order:1 Piece
Shanghai Baudcom Communication Device Co.,Ltd.
Features:Features:
◆ Uniform power splitting
◆ Compact package dimension
◆ Low polarization dependent loss
◆ Good channel-to-channel uniformity
◆ Environmentally and mechanically stable
◆ Low Insertion Loss and high Return Loss
◆ Wide operating wavelength range from1260nm to 1650nm
Standard:
◆ Telcordia GR-1209 and GR-1221
Application:
◆ Telecommunication networks
◆ FTTX, FTTH (Fiber to the Home)
◆ PON (Passive Optical Network)
◆ LAN & WAN
◆ CATV
Specifications:
Table 1: Performance for 1×N PLC Splitter
Note: All measurements are done at room temperature without connectors.
Port Configuration | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | |
Operating Wavelength (nm) | 1260~1650 | ||||||
Insertion Loss (dB) | Typ. | 3.6 | 6.8 | 10.0 | 13.0 | 16.0 | 19.5 |
Max. | 4.0 | 7.3 | 10.5 | 13.7 | 16.9 | 21.0 | |
Loss Uniformity (dB) | Typ. | 0.4 | 0.5 | 0.5 | 1.0 | 1.0 | 1.5 |
Max. | 0.6 | 0.6 | 0.8 | 1.2 | 1.5 | 2.5 | |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
PDL (dB) | Typ. | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 | 0.2 |
Max. | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.4 | |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
Fiber Length (m) | 1.0 or customized | ||||||
Fiber Type | Corning SMF-28e or customized | ||||||
Wavelength Dependent Loss (dB) | Typ. | 0.2 | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 |
Max. | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 | |
Temperature Stability (-40~+85°C) (dB) | Typ. | 0.3 | 0.3 | 0.3 | 0.4 | 0.4 | 0.4 |
Max. | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | |
Operating Temperature (°C) | -40~+85°C | ||||||
Storage Temperature (°C) | -40~+85°C |
Table 2: Performance for 1×N PLC Splitter
Note: All measurements are done at room temperature with connectors.
Port Configuration | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | |
Operating Wavelength (nm) | 1260~1650 | ||||||
Insertion Loss (dB) | Typ. | 4.0 | 7.0 | 10.3 | 13.5 | 16.5 | 20.0 |
Max. | 4.5 | 7.7 | 11.0 | 14.2 | 17.5 | 21.5 | |
Loss Uniformity (dB) | Typ. | 0.4 | 0.5 | 0.5 | 1.0 | 1.0 | 1.5 |
Max. | 0.6 | 0.6 | 0.8 | 1.2 | 1.5 | 2.5 | |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
PDL (dB) | Typ. | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 | 0.2 |
Max. | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.4 | |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
Fiber Length (m) | 1.0 or customized | ||||||
Fiber Type | Corning SMF-28e or customized | ||||||
Wavelength Dependent Loss (dB) | Typ. | 0.2 | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 |
Max. | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 | |
Temperature Stability (-40~+85°C) (dB) | Typ. | 0.3 | 0.3 | 0.3 | 0.4 | 0.4 | 0.4 |
Max. | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | |
Operating Temperature (°C) | -40~+85°C | ||||||
Storage Temperature (°C) | -40~+85°C |
Table 3: Performance for 2×N PLC Splitter
Note: All measurements are done at room temperature without connectors.
Port Configuration | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 |
Operating Wavelength (nm) | 1260~1650 | |||||
Insertion Loss (dB) | 4.0 | 7.6 | 11.0 | 14.5 | 17.5 | 21.0 |
Loss Uniformity (dB) | 0.8 | 1.5 | 1.5 | 2.0 | 2.5 | 2.5 |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
PDL (dB) | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.4 |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
Fiber Length (m) | 1.0 or customized | |||||
Fiber Type | Corning SMF-28e or customized | |||||
Wavelength Dependent Loss (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Temperature Stability (-40~+85°C) (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Operating Temperature (°C) | -40~+85°C | |||||
Storage Temperature (°C) | -40~+85°C |
Table 4: Performance for 2×N PLC Splitter
Note: All measurements are done at room temperature with connectors.
Port Configuration | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 |
Operating Wavelength (nm) | 1260~1650 | |||||
Insertion Loss (dB) | 4.5 | 8.1 | 11.6 | 15.0 | 18.0 | 21.5 |
Loss Uniformity (dB) | 0.8 | 1.5 | 1.5 | 2.0 | 2.5 | 2.5 |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
PDL (dB) | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.4 |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
Fiber Length (m) | 1.0 or customized | |||||
Fiber Type | Corning SMF-28e or customized | |||||
Wavelength Dependent Loss (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Temperature Stability (-40~+85°C) (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Operating Temperature (°C) | -40~+85°C | |||||
Storage Temperature (°C) | -40~+85°C |
Ordering Information:
Name | PLC=PLC Splitter |
Port | 12=1×2; 14=1×4; 18=1×8; 116=1×16; 132=1×32; 164=1×64; 1128=1×128; 22=2×2; 24=2×4; 28=2×8; 216=2×16; 232=2×32; 264=2×64; 2128=2×128 |
Number of PLC Splitter | None=1pc; 2=2pcs; 3=3pcs; 4=4pcs; etc |
Package | R=Rack Mount |
Dimension | 1=1U; 2=2U; 3=3U; 4=4U; 5=5U |
Access | F=Front Access; B=Back Access |
Fiber Mode | 2A=SM G.652.A; 2B=SM G.652.B; 2C=SM G.652.C; 2D=SM G.652.D; 5A=SM G.655.A; 5B=SM G.655.B; 5C=SM G.655.C; 7A1=SM G.657.A1; 7A2=SM G.657.A2; 7B2=SM G.657.B2; 7B3=SM G.657.B3 |
Connector & Adaptor | SU=SC/UPC; SA=SC/APC; FU=FC/UPC; FA=FC/APC; TU=ST/UPC; TA=ST/APC; LU=LC/UPC; LA=LC/APC; etc None=without connectors |
Ordering information
BD-SPLITTER-32 | 1:32 fiber splitter, 1.5 meter pigtail fiber, SC onnector, 19inch rack mount |
BD-SPLITTER-16 | 1:16 fiber splitter, 1.5 meter pigtail fiber, SC onnector, 19inch rack mount |
BD-SPLITTER-08 | 1:8 fiber splitter, 1.5 meter pigtail fiber, SC onnector, 19inch rack mount |