Modular Calibration Of 1-Phase Energy Meter With Remotely Update Software
Negotiable /Piece
Min.Order:1 Piece
Modular Calibration Of 1-Phase Energy Meter With Remotely Update Software
Product Profile:
All kinds of active/reactive energy meter can be calibrated.
Main Features:
Automatically or single-step manually test basic error, Creeping, start, standard deviation of single/three phase energy meter, besides, automatically testing can be self-defined by user; Automatic Calibration System can be customized according to customer\'s requirements; Exchange the testing settings and testing records thru U disk(or SD card); Accuracy :U, I, P, Kwh : ±0.05%; Q, Kvarh : ±0.1%; U, I, P stability : 0.01%RG/3min, AC Voltage and AC Current distortion : ≤0.2%; Current scope: Min. 0.05A, Max. 100A(Max output 120A); Voltage 57.7V-380V; Export 2nd-63rd harmonics, and measure & analyze the harmonics; With OCXO daily error of energy meter can be detected; 7\" color touch screen, interface friendly, easy to operate; Equipped with RS232 & Ethernet interface, AT6025C can be operated either stand-alone, or controlled by PC; Remotely updating online, easily achieve software updating; Equipped with barcode gun interface, parameters of tested meters can be easily scanned in; Communicate with tested meters thru RS485, Ethernet, RS232; Self-protection, alarming and displaying overload location for equipment output overload, Voltage short-circuit, Current open-circuit; Self-diagnosis for amplifier failure and internal module communication failure; Test 3 energy meters with the same model type at one time Test energy meters with the accuracy of Class 0.2 and below (Class 0.05 equipment);Technical Specification
Range |
Capacity |
Adjustment Degree |
Adjustment Range |
Stability |
Distortion (linear load) |
Measurement accuracy |
|
AC Voltage |
57.7V~380V |
30VAmax/ phase |
0.01%RG |
0~120%RG |
0.01%RG 3min CL0.05 0.02%RG 3min CL0.1 |
0.2% CL0.05 0.5% CL0.1 |
±0.05%RG CL0.05 ±0.1%RG CL0.1 |
AC Current |
0.05A~120A |
100VAmax/ phase @100A |
0.01%RG |
0~120%RG |
0.01%RG 3min CL0.05 0.02%RG 3min CL0.1 |
0.2% CL0.05 0.5% CL0.1 |
±0.05%RG CL0.05 ±0.1%RG CL0.1 |
Phase |
0.00°~359.99° |
0.01° |
0.00°-359.99° |
0.01° |
±0.05° |
||
Frequency |
40Hz ~70Hz |
0.002Hz |
40Hz -70Hz |
0.002Hz |
±0.003Hz |
||
Power/Energy |
±0.05%RG CL0.05 ±0.1%RG CL0.1 pf≥0.5 |
||||||
Output Harmonics |
2nd to 63rd |
0 |