3 Phase Electrical Test Meters Calibrators With Wireless Terminal Control

3 Phase Electrical Test Meters Calibrators With Wireless Terminal Control

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
0 Piece / Pieces per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Calibrator Supplier Platform
Place of Origin:
China
Model Number:
Calibrator Supplier Platform

Professional Calibrator Supplier Platform.

Business Type: Trading Company
Main Products:

Product Details

Delivery Time:50 days
Certification:IEC, MID

 
3 Phase Electrical Test Meters Calibrators With Wireless Terminal Control
 


Usage:


AT1022 is suitable for the measurement departments of research institution, generating station, power grid corporation, railway, large industrial and mining enterprises and national measurement institution at all levels.
 

Main function


Calibrate indicating meter, digital meter, electric transducer, energy meter and so on;
Calibrate AC sampling RTU;
Output 2nd~63rd harmonics;
 


Main feature


Modular design, calibrate indicating meter, electrical transducer, RTU and so on;
8 inch color touch screen, interface friendly, easy to operate;
Equipped with RS232, Ethernet, and WiFi interface, AT1022 can either support stand-alone operation, PC 

control or handy wireless terminal control;
Communicate with tested meters thru RS485;
Automatically calculate the error of meter and transducer, and the related data can be downloaded thru 

U-disk;
Self-protection, alarming and displaying overload location for equipment output overload, Voltage short-circuit, Current open-circuit;
Automatically detect, diagnose and alarm for failure. 
Remotely updating online, easily achieve software updating;
Support calibrating by userself. 
 

Type:

AT1022C Electric meter calibrator. Class 0.05

AT1022B Electric meter calibrator. Class 0.1


AC large Voltage output:


Range: (Phase A) 30V, 100V, 300V, 660V, 1000V;
(Phase B, C) 30V, 100V, 300V, 660V;
Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter; Phase A 1000V: (0~100) %RG;
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG for option;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Distortion: ≤0.2% (Non capacitive load);
Max output load: 30V and upper gears; 20VA each phase;
Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
 


 
AC small Voltage output:


Range: Phase A: 75mV, 300mV, 750mV, 3V, 7.5V;
Adjusting range: (0~120) %RG, RG refers to range; 
Adjusting range: 0.01%RG, 0.1%RG, 1%RG, and 10% RG for option;
Stability: 0.02%/2min;
Distortion: ≤0.2% (Non capacitive load);
Max output load: ≥25mA;
Measurement accuracy: 0.1%RG;
 


 
AC Current output:


Range: (Phase A) 500uA, 2mA,10mA, 50mA, 200mA, 500mA, 2A, 5A, 10A, 30A;
(Phase B, C) 200mA, 500mA, 2A, 5A, 10A, 30A; 
Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter; 
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG for option;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Distortion: ≤0.2% (Non capacitive load);
Max output load: 20VA (30A gear); 50mA and below gear: ≥15V;
Measurement accuracy: 200mA and above gears: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1);
                    50mA and below gears: 0.1%RG (Class 0.1);
 
 


Power output


Power output stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Active/reactive power measurement accuracy: 0.05%RG;
 


Phase output


Output adjusting range: 0°~360°;
Output adjusting degree: 10°, 1°, 0.1°, 0.01° for option;
Resolution: 0.01°;
Measurement accuracy: 0.05°.
 


Power factor output:


Adjusting range: -1 ~ 0 ~ +1;
Measuring resolution: 0.0001;
Measurement accuracy: 0.0005
 


Frequency output


Adjusting range: 40Hz ~70Hz;
Output adjusting degree: 1Hz, 0.1Hz, 0.01Hz, 0.001Hz for option;
Resolution: 0.001Hz;
Accuracy: 0.002 Hz.
 


Harmonic setting


Harmonic order: 2nd ~63rd;
Harmonic amplitude: 0~40%;
Harmonic angle: 0°~359.99°;
Harmonic set error: 2nd ~31st: ≤±0.1%,32nd ~63rd: ≤±0.2%;
 


DC Voltage output


Range: 100mV, 300 mV, 1V, 5V, 20V, 100V, 300V, 1000V;
Adjusting range: (0~120) %RG; 1000V: (0~100) %RG
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Output load: 20V and above ranges ≥10mA;5V and below ranges≥50mA;
Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
Ripple content: no more than 1%.  
 


DC Current output


Range: 1mA, 3mA, 10mA, 30mA, 100mA, 300mA, 1A, 5A, 10A, 25A;
Adjusting range: (0~120) %RG;
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Output lo

Contact Supplier

Miss. Stacey sale Manager Chat Now
Telephone
86-755-34371917
Mobile
86-13054698745
Fax
86-755-34371917
Skype
lucky200912
Address
Jielutou Industrial Zone ,Shangwang Street Huzhou,Zhejiang

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electronic Components & Supplies > Electronic Accessories & Supplies > Keypads & Keyboards
Categories
Hi~