3 Phase Electrical Test Meters Calibrators With Wireless Terminal Control
Negotiable /Piece
Min.Order:1 Piece
Intelligent Low Voltage Motor Protection Relay , active & reactive Power Meter Test Equipment
Voltage Meter / Multimeter Electrical Calibrators With 8 Inch Color Touch Screen
Voltage Monitor Test Equipment Electrical Calibrators For Power Grid Corporation
Relay Multifunction Power Calibration Of 1-Phase Energy Meter With RS232 , RS485
Measuring Electrical Energy Meter Calibrator With Barcode Gun Interface
Stand-Alone Wireless Electrical Calibrators , Calibrate Multi Meter Class 0.05 / Class 0.1
3 Phase Electrical Test Meters Calibrators With Wireless Terminal Control
Usage:
AT1022 is suitable for the measurement departments of research institution, generating station, power grid corporation, railway, large industrial and mining enterprises and national measurement institution at all levels.
Main function
Calibrate indicating meter, digital meter, electric transducer, energy meter and so on;
Calibrate AC sampling RTU;
Output 2nd~63rd harmonics;
Main feature
Modular design, calibrate indicating meter, electrical transducer, RTU and so on;
8 inch color touch screen, interface friendly, easy to operate;
Equipped with RS232, Ethernet, and WiFi interface, AT1022 can either support stand-alone operation, PC
control or handy wireless terminal control;
Communicate with tested meters thru RS485;
Automatically calculate the error of meter and transducer, and the related data can be downloaded thru
U-disk;
Self-protection, alarming and displaying overload location for equipment output overload, Voltage short-circuit, Current open-circuit;
Automatically detect, diagnose and alarm for failure.
Remotely updating online, easily achieve software updating;
Support calibrating by userself.
Type:
AT1022C Electric meter calibrator. Class 0.05
AT1022B Electric meter calibrator. Class 0.1
AC large Voltage output:
Range: (Phase A) 30V, 100V, 300V, 660V, 1000V;
(Phase B, C) 30V, 100V, 300V, 660V;
Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter; Phase A 1000V: (0~100) %RG;
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG for option;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Distortion: ≤0.2% (Non capacitive load);
Max output load: 30V and upper gears; 20VA each phase;
Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
AC small Voltage output:
Range: Phase A: 75mV, 300mV, 750mV, 3V, 7.5V;
Adjusting range: (0~120) %RG, RG refers to range;
Adjusting range: 0.01%RG, 0.1%RG, 1%RG, and 10% RG for option;
Stability: 0.02%/2min;
Distortion: ≤0.2% (Non capacitive load);
Max output load: ≥25mA;
Measurement accuracy: 0.1%RG;
AC Current output:
Range: (Phase A) 500uA, 2mA,10mA, 50mA, 200mA, 500mA, 2A, 5A, 10A, 30A;
(Phase B, C) 200mA, 500mA, 2A, 5A, 10A, 30A;
Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter;
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG for option;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Distortion: ≤0.2% (Non capacitive load);
Max output load: 20VA (30A gear); 50mA and below gear: ≥15V;
Measurement accuracy: 200mA and above gears: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1);
50mA and below gears: 0.1%RG (Class 0.1);
Power output
Power output stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Active/reactive power measurement accuracy: 0.05%RG;
Phase output
Output adjusting range: 0°~360°;
Output adjusting degree: 10°, 1°, 0.1°, 0.01° for option;
Resolution: 0.01°;
Measurement accuracy: 0.05°.
Power factor output:
Adjusting range: -1 ~ 0 ~ +1;
Measuring resolution: 0.0001;
Measurement accuracy: 0.0005
Frequency output
Adjusting range: 40Hz ~70Hz;
Output adjusting degree: 1Hz, 0.1Hz, 0.01Hz, 0.001Hz for option;
Resolution: 0.001Hz;
Accuracy: 0.002 Hz.
Harmonic setting
Harmonic order: 2nd ~63rd;
Harmonic amplitude: 0~40%;
Harmonic angle: 0°~359.99°;
Harmonic set error: 2nd ~31st: ≤±0.1%,32nd ~63rd: ≤±0.2%;
DC Voltage output
Range: 100mV, 300 mV, 1V, 5V, 20V, 100V, 300V, 1000V;
Adjusting range: (0~120) %RG; 1000V: (0~100) %RG
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Output load: 20V and above ranges ≥10mA;5V and below ranges≥50mA;
Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
Ripple content: no more than 1%.
DC Current output
Range: 1mA, 3mA, 10mA, 30mA, 100mA, 300mA, 1A, 5A, 10A, 25A;
Adjusting range: (0~120) %RG;
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Output lo