Low Self Discharge High Power Lithium Battery Cells Er18505 For Heat Meter

Low Self Discharge High Power Lithium Battery Cells Er18505 For Heat Meter

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
0 Piece / Pieces per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
HCB
Place of Origin:
China
Model Number:
ER18505

HCB Battery Co., Ltd

Business Type: Trading Company
Main Products:

Product Details

Delivery Time:35 work days
Certification:UN/CE/UL

Low Self Discharge High Power Lithium Battery Cells Er18505 For Heat Meter

Nominal Capacity 4000mAh
Battery discharged at continuous current 2.0mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃
Nominal Voltage 3.6 V
Maximum Continuous Current 150mA
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃
Maximum Pulse Discharge Current 300mA
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃
Storage Condition

Temperature ≤ 30℃

Humidity ≤ 75%RH

Operating Temperature -55℃ to +85℃
Battery Dimension See drawing on pag
Max Weight 31.0g
Self-discharge Rate 2%
Max self-discharged rate at ambient temperature 23±2℃
Shelf Life 10 years
Ambient temperature 23±2℃

1. Battery Characteristic

High Voltage

Each cell nominal voltage up to 3.6V, the working voltage varies with the load, generally between 3.3V ~ 3.6V

High Energy Density

We provide the specific energy density up to 464Wh/kg

Wide Operating Temperature Range

We provide a wide operating temperature range, from -55℃ to +85℃

Stable Operating Voltage

Stable operating voltage, more than 90% of the capacity could be output with a fixed voltage

Long Shelf Life

The battery self-discharge less than 2% per year at room temperature

Battery sealing using the fully sealed structure to reduce the leakage of the battery, make the battery can be stored at room temperature for more than 10 years

2. Main Applications

Infrastructures

Automatic meters (water meter, electric meter, gas meter), conventional meters, etc.

Oil & gas

Well pressure meters in high temperature, float meter, logging while drilling (LWD), measure while drilling (MWD), etc.

Medical devices

Cardiac pacemaker, respirator, oxygenator, inspection devices, monitoring devices, infusion pump, etc.

3. Manufacturing Advantages

Advanced automatic technology is used in HCB; Excellent control of passivation; We can produce high power, high capacity or high temperature batteries and so on; Providing multiple cascade and parallel connecting ways and combining suggestions; We have designed multiple safety solutions for Li-SOCl2 Battery. We have more than 20 years experience in the industrial technology of Li-SOCl2 batteries.

4. Company Advantages

GB/T19001-2008/ISO9001:2008 is HCB quality management system standard; GB/T24001-2004/ISO14001:2004 is HCB Environment Management System standard; We have much experience in drop test package; The goods can be transported very safely because we can provide the report for the customers' reference; The CE certificate can be given to you if required; The Rosh certificate can be given to you if required; The UL certificate can be given to you if required;

5. FAQS of General Safety Instructions

Is it possible to store the battery in moist environment?

The Battery should be stored in dry environment.

If you have children at home, what should you pay attention when we use our battery?

You need to keep battery out of the children. Please call to a physician immediately if it is swallowed by children.

If the batteries are closed to the fire, what may happen?

The batteries may be incinerated or mutilated if they are closed to the fire and it leads a possible burst or they may release the toxic materials.

If the positive and negative polarity of a battery is directly connected, what will happen?

If + and - polarity of battery is connected directly, it causes a short circuit and this may lead toxic gas and materials leakage or a big rupture.

Can the batteries be mixed to use on different electrochemical system, grades or brands?

When changing batteries be aware that batteries of different electrochemical system, grades, or brands should be not mixed. If different batteries are used or in case of using old and new batteries together this can discharge batteries due to different voltage or capacity. This can cause toxic material or gas leakage and/or violent rupture.

Is it able to solder the batteries together directly?

In this case the battery can be damaged by the heat. This can lead short circuit and a toxic materia

Contact Supplier

Mr. Johnson Jing sale Manager Chat Now
Telephone
86-27-83248452
Mobile
86-18171268930
Fax
86-27-83248455
Skype
johnson@cnhcb.com
Address
No.1 Special Taizhong Avenue, Gaoqiao Industrial Park Tongchuan,Shaanxi

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Hi~