Delivery Time:10 work days (According to the order quantity )
Certification:CE FCC
Dc to ac single phase pure sine wave inverter rechargeable inverter 1000w-6000w
Model : HI-10212
Adjustable mains priority and inverter priority mode:
Mains priority: When AC mains and DC battery are connected at the same time, inverter chooses AC mains for priority AC output.
Inverter priority: When AC mains and DC battery are connected at the same time, inverter converts DC battery power for priority AC output.
Customers can choose mains priority or inverter priority mode according to their own needs, and can switch them at any time.
Brand new and imported U.S. brand Infineon IR MOSFETs are used for the whole series:
1000W-3000W:US IR brand MOSFETs
4000W-6000W:US IR brand COOL MOS 3077 MOSFETs, higher level MOSFETs
HI Series Wall-mounting Low Frequency Pure Sine Wave Inverter (220V) | |||||||||||
Model | HI-351 | HI-501 | HI-601 | HIS-801 | HI-102 | HIS-122 | HI-152 | HI-202 | HI-302 | HI-502 | |
Rated Power | 350W | 500W | 600W | 800W | 1KW | 1.2KW | 1.5KW | 2KW | 3KW | 5KW | |
Peak Power | 700W | 1000W | 1200W | 1600W | 2KW | 2.4KW | 3KW | 4KW | 6KW | 10KW | |
Nominal battery voltage | 12VDC | 12VDC/24VDC | 24VDC/48VDC | 48VDC | |||||||
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) | |||||||||
AC Mains input range | (220/230/240VAC) 140-275VAC | ||||||||||
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz (50Hz/60Hz automatic recognition) | ||||||||||
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm | |||||||||
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown | ||||||||||
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm | ||||||||||
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown | ||||||||||
Over load protection | 110% more than rated capacity, automatic shutdown | ||||||||||
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown | ||||||||||
Short circuit protection | Automatic shutdown | ||||||||||
Output | Transfer efficiency | ≥87% | |||||||||
Output voltage | (DC battery mode) 220/230/240VAC±2% | ||||||||||
Output frequency | (DC battery mode) 60/50Hz±1% | ||||||||||
Output wave form | Pure sine wave | ||||||||||
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) | ||||||||||
AVR output stablizer | AC mains<140VAC±5% swtich to DC battery mode, AC mains>150VAC ±5% return to AC mains mode; | ||||||||||
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; | |||||||||||
The above is for output 220V system reference, 230V/240V output just multiply by percentage | |||||||||||
Output frequency | (AC mains mode) automatic tracing from AC input | ||||||||||
Other | Transfer time | ≤8ms | |||||||||
Display | LCD Display with function buttons | ||||||||||
Cooling system | Intelligent cooling fan control system | ||||||||||
≤42℃ slow fan, ≥45℃ fast fan | |||||||||||
AC Charger | AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) | |||||||||
AC charging current | Steady 15A | ||||||||||
AC over charge protection | Battery ≧16V (12V) ≧32V (24V) ≧64V (48V), stop charging after 60s alarm | ||||||||||
Working mode (Optional) |
01 | AC mains priority | |||||||||
Always use AC mains as priority input to provide AC output and automatically char
You May Like