Model Selection and Differences
Specifications
Model |
WST1211 |
Working Temperature |
-40℃~+75℃ |
Voltage |
220V±10%, 110V±10%, 50/60HZ |
Rated power |
80W |
Relative humidity |
≤90% |
Remote control distance |
≥30m |
Net weight |
48kgs |
Speed |
1S,1.8S,3S, 6S |
Max boom length |
6 meters |
Motor Rotational speed |
1400rmp |
Protection Degree |
IP44 |
Communication with customers
1) Q: Connected power and press open/close button but traffic barrier gate no action?
A |
Reason |
Solution |
1 |
Fuse blown |
Check fuse and power in controller |
2 |
Battery of remote control powered off |
Change a new one |
3 |
External protection circuit break or at protecting status |
Open the barrier door and click OPEN/CLOSE button on control box |
4 |
Same frequency interference |
Check photocell and loop detector |
2) Q:Connected power and press open/close button,traffic barrier gate will move but even when it is at right position, the motor still running and not stop?
A |
Reason |
Solution |
1 |
Limit switch |
Adjust the horizontal/vertical limit switch to correct position |
2 |
Main controller failure |
Change a new one |
3) Q: Motor running but traffic barrier gate arm no action?
A |
Reason |
Solution |
1 |
Barrier arm at 45° position where is hard to move |
Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
2 |
Tension of balancing spring not suitable |
Adjust spring exactly |
3 |
Low working voltage |
Check the voltage and power |
4) Q: When opening/closing,traffic barrier gate arm cannot reach right position (90° vertical & 180° horizontal)?
A. |
Reason |
Solution |
1 |
Length adjustment of connecting rod not correct |
Open barrier door and unlock clutch to check when arm at 90° vertical position if the master rod covers slave one; when arm at 180° horizontal position if master rod and slave one are in the same straight line |
2 |
Nuts on the limit switch loose |
Tighten the nuts when arm at 90° vertical and 180° horizontal |