Security Access Control 4s Vehicle Barrier Gate 120W High Sensitive
Negotiable /Piece
Min.Order:1 Piece
Shenzhen Wonsun Machinery & Electrical Technology Company Limited
Boom Backtrack 8 meters 220V Vehicle Barrier Gate IP44 Aluminum Alloy Straight
AC110V / 220V Automatic Vehicle Barrier Gate For Highway Toll System
Automatic And Electronic Drop Arm Barrier For Highway Or Toll Gate System
Vehicle Access Control Vehicle Barrier Gate With Max 6m Straight Arm
180 Degree Folding Arm Nice Automatic Barrier Gate CE / ISO SGS Approved
Durable Manual Barrier Gate Arm Barrier For Toll And Parking Lot
Security Access Control 4s Vehicle Barrier Gate 120W High Sensitive
1. steady function, sensitive reaction, low noise
2.The case shell is made of thickened steel which is shaped by 13 process flow. Without fading ,waterproofing, not rusty, durable.
3.high sensitive limit switch, pole can be instant turn on and off .accurate location.
ntrol system adopts hi-tech digital chip technology.
5. the anti-collision function. Protecting the passenger
6. the inductive function ,with the digital vehicle detector
7.the movements adopts the most steady running mode –non-constant speed mode. Or the variable speed excogitation. (Slow – quick – slow ) .This function makes the operation steady and prolongs the working life.
Model Selection and Differences
Specifications
Model |
WST1211 |
Working Temperature |
-40℃~+75℃ |
Voltage |
220V±10%, 110V±10%, 50/60HZ |
Rated power |
80W |
Relative humidity |
≤90% |
Remote control distance |
≥30m |
Net weight |
48kgs |
Speed |
1S,1.8S,3S, 6S |
Max boom length |
6 meters |
Motor Rotational speed |
1400rmp |
Protection Degree |
IP44 |
Communication with customers
1) Q: Connected power and press open/close button but traffic barrier gate no action?
A |
Reason |
Solution |
1 |
Fuse blown |
Check fuse and power in controller |
2 |
Battery of remote control powered off |
Change a new one |
3 |
External protection circuit break or at protecting status |
Open the barrier door and click OPEN/CLOSE button on control box |
4 |
Same frequency interference |
Check photocell and loop detector |
2) Q:Connected power and press open/close button,traffic barrier gate will move but even when it is at right position, the motor still running and not stop?
A |
Reason |
Solution |
1 |
Limit switch |
Adjust the horizontal/vertical limit switch to correct position |
2 |
Main controller failure |
Change a new one |
3) Q: Motor running but traffic barrier gate arm no action?
A |
Reason |
Solution |
1 |
Barrier arm at 45° position where is hard to move |
Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
2 |
Tension of balancing spring not suitable |
Adjust spring exactly |
3 |
Low working voltage |
Check the voltage and power |
4) Q: When opening/closing,traffic barrier gate arm cannot reach right position (90° vertical & 180° horizontal)?