Commercial Single Phase Power Meter Multi - Function Smart Electric Meters
Negotiable /Set
Min.Order:1 Set
Split Type STS Single Phase Electric Meter , Plc G3 Rf Din Rail Power Meter
Low Voltage Prepaid Electricity Meters , Sts Digital Electric Meter Safety
Card Prepayment Single Phase Electric Meter , Surge Protection Wireless Power Meter
Low Voltage 3 Phase Electric Meter / Backlit LCD Surge Safe Sts Keypad Meter
Ultrasonic Welded 3 Phase Electric Meter , 3 Element 4 Quadrant STS Prepayment Meter
Surge Safe Din Rail Kwh Meter Single Phase , Anti Tamper STS Prepaid Meters
Commercial Single Phase Power Meter Multi - Function Smart Electric Meters
The CA168-M is a perfect integration of high precision metrology and state-of-the-art wireless communication technology. It is a single phase two wires electric meter completed in a BS footprint mounting keypad based case with 13kV surge & lightening protection features and 30Vm of RF immunity withstand, being able to operate in very severe environment for residential and light commercial industrial applications.
The CA168-M is provided with a plug & play module for communications . This modular design provides utility and service providers free choice of PLC/RF/GPRS communication and 3G / 4G LTE cellular data networks according to local infrastructure conditions, which greatly reduces their operational cost. The module can be easily removed and replaced without changing the entire meter. Through its wireless communication with an AMR AMI back-end server, a utility and service provider is offered freedom of management settings inclusive of ,but not limited to, free basic unit, emergency credit, repayment control, power limit, TOU rate, automatic meter readout, etc.
Main Features
a) 4 quadrant measurement import & export Absolute / Wh, Varh, Vah
b) Prepayment and post-payment mode toggle
c) Maximum demand measurement as MD ( Optional)
d) Fraud protection against magnetic immunity, and reverse connection (SRE)
e) Data retention in outage, cover open detection
f) Surge protection against lightening
g) IEC 62056-21 and remote readout and control from the server side
Utility benefits
1) Easy installation for retrofitting using existing wires and BS mounting
2) Load management on demand and remote with communication module
3) Reduce operational and maintenance cost
4) Choose suitable communication according to local needs
5) Flexible consumer contractual control settings
Specifications:
Nominal voltage Un |
220/230/240 V |
Limited voltage |
70%~120%Un |
Nominal frequency fn |
50-60Hz+5% |
Basic current(Ib) |
5-10A |
Maximum current(Imax) |
60-100A |
Starting current(Ist) |
20mA |
Active energy constant |
1000imp/kWh |
Accuracy as Active energy to IEC62053‐21 |
Class1.0 |
Power consumption in Voltage circuit |
<2W <8VA |
Power consumption in current circuit |
<1VA |
Operating temperature |
25℃ to+70℃ |
Storage temperature |
40℃ to+85℃ |
Insulation level |
4kV rms for 1min |
Impulse voltage withstand |
8kV, 1.2/50 μs |
Air discharge |
16kV |
Immunity to HF fields |
|
80MHz to 2GHz with load |
10V/m |
100kHz to 1GHz without load |
30V/m |
Fast transient burst test |
4kV |
Meter shell Protection Rate |
IP54(IEC60529) |
Insulation System Classification |
Protective Class II |