Card Type Single Phase Kwh Meter Prepayment Residential Electric Meters
Negotiable /Piece
Min.Order:1 Piece
Extended Flush Type Single Phase Electric Meter / Digital Electricity Meter
Load Switch Single Phase Electric Meter , Prepayment Electricity Meters
Anti - Tamper Single Phase Electric Meter , MCB connected STS Prepaid Meters
Entry Level Single Phase Electricity Meter 1600 Pulse Rate STS Prepayment Meter
DLMS / COSEM Load Profiling Digital Kwh Meter 2.5 KG Prepaid Electricity Meters
Gsm Ethernet Smart Power Meter 3 Phase Residential Power Meter With Icons
Card Type Single Phase Kwh Meter Prepayment Residential Electric Meters
The CA168-C is a single phase two wire card prepayment wat-hour meter. It is used for low voltage residential applications. The meter adopts latest 3DES encryption technology and STS (Standard Transfer Specification) standards with increased security protection for both hardware and software. Thanks to an improved broad range of measurable current 5(80)Amp, and the rugged RF immunity withstand of 30V/m, the meter is able to operate in very harsh environments.
The meter is built in a BS8565 footprint compact housing and maintains IP54 rating protective class, allowing it to be installed in harsh environments. The meter closure is made of polycarbonate fire resistant material and durable for 15 years\' lifespan.
Features
1) Bi-directional measurement of significant reverse energy (SRE)
2) Disconnects on overload and credit expires or exhausts
3) Preset power limit and low credit warning
4) Emergency credit overdraft and repayment control
5) Tamper detection: opening cover, reverse connection, power failure and etc.
Key benefits
a) Compact and easy to install
b) Ideal for retrofitting of BS footprint mounting credit meters
c) Wide dynamic range 5(80)A
d) Time of Use (TOU) , multi-tariff, holiday setting
e) Flexible consumer\'s contract to budget usage limit
f) 15 year designed life
Specifications:
Nominal voltage Un |
220/230/240 V |
Limited voltage |
70%~120%Un |
Nominal frequency fn |
50-60Hz+5% |
Basic current(Ib) |
5-10A |
Maximum current(Imax) |
60-100A |
Starting current(Ist) |
20mA |
Active energy constant |
1000imp/kWh |
Accuracy as Active energy to IEC62053‐21 |
Class1.0 |
Power consumption in Voltage circuit |
<2W <8VA |
Power consumption in current circuit |
<1VA |
Operating temperature |
25℃ to+70℃ |
Storage temperature |
40℃ to+85℃ |
Insulation level |
4kV rms for 1min |
Impulse voltage withstand |
8kV, 1.2/50 μs |
Air discharge |
16kV |
Immunity to HF fields |
|
80MHz to 2GHz with load |
10V/m |
100kHz to 1GHz without load |
30V/m |
Fast transient burst test |
4kV |
Meter shell Protection Rate |
IP54(IEC60529) |
Insulation System Classification |
Protective Class II |