Product Details

HM1500LF Relative Humidity Sensor

Brand Name Humirel
Place of Origin France
Model Number HM1500LF
Usage Temperature Sensor

Product Features

HM1500LF Probe Style Relative Humidity Sensor Module DESCRIPTION

Based on the rugged HS1101LF capacitive humidity sensor, HM1500LF is a dedicated humidity transducer designed for OEM applications where a reliable and accurate measurement is needed. Direct interface with a micro-controller is made possible with the module's linear voltage output.

HM1500LF Probe Style Relative Humidity Sensor Module FEATURES 
• Small size product
• Product free from Lead, Cr(6+), Cd and Hg
• Humidity calibrated within +/-2% @55%RH
• Typical 1 to 3.6 Volts DC output for 0 to 100 % RH at 5 V DC supply
• Ratiometric to voltage supply from 4.75Vdc to 5Vdc.
• Patented solid polymer structure 
• Full interchangeability
• High reliability and long term stability
• Not affected by water immersion
• Very low temperature dependence
• Suitable for 3 to 10 Vdc supply voltage


Humidity Sensor Specfic Features
• Instantaneous de-saturation after long periods in saturation phase.
• Fast response time.
• Part could be washed with distilled water.


HM1500LF Probe Style Relative Humidity Sensor Module APPLICATIONS
• Industrial
• Process control
• … 


HM1500LF Probe Style Relative Humidity Sensor Module PERFORMANCE SPECS

MAXIMUM RATINGS

Ratings

Symbol

Value

Unit

Storage Temperature

Tstg

-30 to 70

°C

Storage Humidity

RHstg

0 to 100

% RH

Supply Voltage (Peak)

Vs

10

Vdc

Humidity Operating Range

RH

0 to 100

% RH

Temperature Operating Range

Ta

-40 to 60

°C


ELECTRICAL CHARACTERISTICS
(Ta=23°C, Vs=5Vdc +/-5%, RL>1MΩ unless otherwise stated) 


Humidity Characteristics

Symbol

Min

Typ

Max

Unit

Humidity Measuring Range

RH

0


100

%RH

Relative Humidity Accuracy (10 to 95% RH)

RH


+/-3

+/-5

%RH

Supply Voltage (regulated at 5Vdc*)

Vs


5


Vdc

Nominal Output @55%RH (at 5Vdc)

Vout

2.42

2.48

2.54

V

Current consumption

Ic


1.4

2

mA

Temperature Coefficient (10 to 50°C)

Tcc


- 0.05

-0.1

%RH/°C

Average Sensitivity from 33% to 75%RH

ΔVout/ΔRH


+26


mV/%RH

Sink Current Capability (RL=33kΩ)

Is



150

µA

Humidity Hysteresis




 +/-1

%RH

Time Constant (at 63% of signal, static) 33% to 75%RH
τ


10
s

Warm up time (electronic)

tw


150


ms

Humidity resolution



0.4


%RH

Output Impedance

Z


70



*Maximum power supply ramp up time to Vcc should be less than 4ms.