Water-cooled water chiller unit (heat recovery selected)
Negotiable /Square Meter
Min.Order:1 Square Meter
china lvte air conditioning system co.,ltd
Water-cooled water chiller unit (heat recovery selected)
Cooling capacity: 400-1744KW
Heating capacity: 388-1680KW
Compressor: Imports semi-closed screw (selected by requirements)
Refrigerant: R22 R134a R407C (selected by requirements)
Power: 3/N/PE AC380V/220V 50HZ/60HZ (changed by requirements)
1. Heat source comes from Tap-water. An additional heat recovery is available.
2. In the general conditions, the temperature should be 30℃-6 5℃.It takes 30% to 80% of the cooling for recoverable heat capacity. When the water temperature is 55 ~60 ℃, the heat capacity is 30% recyclable. Heat recovery system can be installed directly on the central air conditioning units with water softened process function and preventing scaling function.
3. A variety of tooth structure with specially designed copper tube heat exchanger, compact shape, and compact structure. Complete models can be produced according to customer special require.
4. Computer control system with human nature, high and low pressure protection switch, over-current electrical appliance, exhaust temperature switch, oil pressure differential control, water flow switches, phase sequence protection, safety valves, fuses and other protective measures.
5. Adopt-stage or steeples capacity control range is from 0 ~25% ~50% ~75% to 100% of cold adjustment which ensure to meet the match and refrigerator running smoothly.
6. Provide hot water using waste heat, greatly reducing the heating boiler to the atmosphere CO2 emissions, reducing the greenhouse effect.
7.Part of the compressor through the heat recovery heat absorption after reduction of the original condenser heat load, heat exchange efficiency, improve the efficiency of air conditioning units, power consumption is also significantly reduced; same time, the use of heat recovery technology, the units meet the reduced useful life expectancy.
Note: 1.The nominal cooling conditions Inlet and outlet temperature of chilled water is 12 / 7℃ Inlet and outlet temperature of cooling water is 30/35℃. Heat recovery Inlet and outlet temperature of hot water is 40/45℃. Other working parameters, please consult us.2. Protector: high-low-pressure switch, Anti-frost Protector, Soluble Chock, overload Protector, Coil Overheat Protector, Automatic Temperature Sensitive Switchman-phase Protector.