Power Plant Equipment Air Preheater Transmission Frequency Conversion Control System
Negotiable /Piece
Min.Order:1 Piece
HiWING Mechanical & Electrical Technology Corp
Air Preheater Hotspot Detecting System Power Plant Equipment For Air Preheater
Air Preheater Power Plant Equipment , Air Leakage Control System
Pneumatic Actuator Power Plant Equipment , Rapid Switch Valve
Intelligent valve positioner Power Plant Equipment With High Temperature Linear
Rapid Switch Valve Power Plant Equipment Used For Boiler Combustor
Intelligent Valve Positioner Power Plant Equipment With Fast Valve Technology
The Air Preheater Transmission Frequency Conversion Control System(is a transmission control device using transducer to realize soft startup of rotary air preheater,is applicable for supporting and reconstruction of air preheaters in 65MW~1100 MW thermal power generator set and also applicable for transmission control of GGH in desulfurizing system.)
Key words:Air Preheater
Transmission Frequency Conversion Control System
The Air Preheater Transmission Frequency Conversion Control System is a transmission control device using transducer to realize soft startup of rotary air preheater. It has many advantages including big torque, small mechanical impact and power grid impact, stable and reliable operation and so on. It is an ideal transmission control system for rotary air preheater and similar high inertia loads. The system has three grades, i.e. high speed, low speed and debugging, so that different operation requirements can be met. The primary motor and the standby motor can be switched automatically. The standby motor can be switched to the standby motor automatically when the main motor is in fault. The system has two operation modes called remote and local. There is a changing switch in the control cabinet. It can give the primary motor and the standby motor running current signal; The system can output the alarm signal when the transducer is in fault, motor overload or the rotor stops, and it will never stop if overvoltage appears.
Application fields
The Air Preheater Transmission Frequency Conversion Control System is applicable for supporting and reconstruction of air preheaters in 65MW~1100 MW thermal power generator set and also applicable for transmission control of GGH in desulfurizing system.
Technical parameters
Parameters |
Value |
Remark |
Power of transducer |
≥7.5kW |
|
Power supply |
AC 380V/400V/415V 50Hz |
Two three-phase four-wire lines, (for production and security) |
Output load |
5A /AC 240V 5A /DC 28V |
|
Ambient temperature |
-10℃~50℃ |
|
Relative humidity |
<85% |
|
Degree of protection |
IP56 |
Domestic and international cooperation projects
Shandong Chiping Xinyuan power plant 2x330MW project.
Xinjiang Kashi power plant 2x350MW project.
Xiangtan power plant air preheater reconstruction project.
Philippines Mariveles power plant 2x325MW project.
Indonesia Awar power plant 2x350MW project.
Russia Troitsk power plant 1x660MW project.