Industrial C2H2 / SO2 / CO2 / Oxygen Air Separation Plant 330KW 50HZ
Negotiable /Piece
Min.Order:1 Piece
HANG ZHOU TAI LIAN CRYOGENIC EQUIPMENT CO., LTD.
SO2 / H2S / C2H2 Air Separation Plant liquid Oxygen Plant 720Y-1500
High Pressure Industrial Ultra LNG Vaporizer With Single Evaporation Set
Environmental Heat Exchange LPG / NH3 / LNG Vaporizer 0.8-100MPa
High Efficiency Automatic Cryogenic Liquid Pump For L-CNG Cylinders Filling
High Pressure L-CNG Liquid Refrigerant Pump 1.6MPa 5000-30000L/h
Large Flow Low Noise Cryogenic Liquid Pump 0.02-1.2MPa 1.6-5MPa
99.6% Air Separation Plant Industrial KDON-350/800 Oxygen Plant With Low Energy Consumption
Atmosphere pressure 96kPa(A)
Atmosphere tempt. 25℃
Relative humidity 75%
O2 contained in air 20.95%O
Annual average tempt. 18.4℃
Max. Tempt. 45℃
Min. Tempt. -15℃
Average tempt. in Summer 25℃
Average tempt. in Winter -15℃
Earth shake : <6 Mcalli degree
Sea level: 425m
Impurity in atmosphere:
CO2 ≤300 ppm
SO2 ≤0.44 mg/m3
H2S ≤2.3 mg/m3
CH4 ≤5.2mg/m3
C2H2 ≤0.03 ppm
CnHm(Except C2H2) ≤5 ppm
Dust content ≤10mg/m3
1.6 Recycling water
Inlet tempt. 30℃
Inlet pressure 0.4 MPa(G)
Max. pressure drop 0.2 MPa(G)
Max. tempt. rising 10℃
Turbidity of cooling water 12 mg/L
PH value 7.2
Total hardness 2.5
Fouling factor 0.0004 m2 hºC/ kW
Water consumption: 180T/h Recycling water ~25T/h(not incl. O2 compressor)
Power supply
HV power supply 10kV±5%
LV power supply 380V/220V±5%
Frequency 50±0.5Hz
Loaded power ~330KW(Name plate not iccl.
O2compressor)
2. Main technical parameters
2.1 Output and purity, pressure(out of the cold box)
O2 output 350m3/h±5%
O2 purity ≥99.6%O2
O2 pressure ~0.034MPa(G)
N2 output 800m3/h±5%
N2 purity ≤10ppmO2
N2 pressure ~0.012 MPa(G)
Product output status(at 0℃,101.325Kpa)
Start pressure 0.65MPa(G)
Continuous operation period between two defrosting times 12months
Start time ~24 Hours
Specific power consumption ~0.64kWh/mO2(not incl. O2 compressor)
3. Process description:
KDON-350/500 air separation plant is of low pressure process.
Raw air comes from air, goes through air filter for removal of dust andother mechanical particle and enters non-lub air compressor to be compressed by two stage compressor to approx. 0.65MPa(g).It goes through cooler and enters precooling unit to be cooled to 5~10℃. Then it goes to switch-over MS purifier for removal of moisture, CO2, carbon hydrogen. Purifier consists of two molecular sieve filled vessels. One is in use while anther is under regeneration by waste nitrogen from the cold box and through heater heating.
After purified, small part of it is used as bearing gas for turbine expander, other enters cold box to be cooled by reflux(pure oxygen, pure nitrogen and waste nitrogen) in main heat exchanger. Part of air is abstracted from the middle part of main heat exchanger and goes to expansion turbine for production of cold. Most of expanded air goes through subcooler which is cooled by oxygen from upper column to be delivered to upper column. Small part of it goes through bypass to waste nitrogen pipe directly and is reheated to go out of the cold box. The other part of air continues to be cooled to near liquid air tempt to lower column.
In lower column air,air is separated and liquified as liquid nitrogen and liquid air. Part of liquid nitrogen s abstracted from the top of the lower column. Liquid air after subcooled and throttled is delivered to the middle part of upper column as reflux.
Product oxygen is abstracted from the lower part of upper column and reheated by expanded air subcooler, main heat exchange. Then it is delivered out of column. Waste nitrogen is abstracted from the upper part of upper column and is reheated in subcooler and main heat exchanger to go out of column. Part of it is used as regeneration gas for MS purifier. Pure nitrogen is abstracted from the top of the upper column and is reheated in liquid air , liquid nitrogen subcooler and main heat exchanger to be delivered out of the column.
Oxygen out of the distillation column is compressed to customer.
4. Scope of supply:
Air non-lub. compressor 2 sets
Air discharge 1320 m³/h
Normal operation pressure ~0.70 MPa
Total power loaed 132 KW
Dim. 2650×1600×1800 mm
Scope of supply:
.1 Main machine
2 Spare parts 1 x2
3,Oil spray filter 1 Pc
Air precooling unit 1 Group
T