Calibration Close-Link Three Phase Meter Test Bench with 6-12-24-48 Meter Positions

Calibration Close-Link Three Phase Meter Test Bench with 6-12-24-48 Meter Positions

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
0 Piece / Pieces per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
GENY
Place of Origin:
China
Model Number:
YC1893DI

Guangzhou GENY Electric Co., Ltd.

Business Type: Trading Company
Main Products: Meter Testing Equipment ,Electric Meter Test Equipment ,Portable Meter Test Equipment

Product Details

Delivery Time:30 days after order confirmed
Certification:ISO 9001
Specifications: Accuracy class : 0.05 Easy to calibrate closed I-P link meters with isolated current transformer(ICT)

Technical spec.

YC1893D-ICT-6

YC1893D-ICT-12

YC1893D-ICT-24

YC1893D-ICT-48

 ICT

6

12

24

48

Accuracy class of ICT

0.05 / 0.01

Accuracy

0.05

Power Source

YCS-103-250

YCS-103-600

YCS-103-1200

YCS-103-2500

Standard Meter

SZ03A-K6 / SZ03A-K8 (customized)

Scanning Head

YCG-S Series

Voltage

 

Test voltage output(Phase-Neutral)

3x(24V~288V)(or customized)

Power of the voltage output

Max. 3x100VA

Max. 3x250VA

Max.

3x500VA

Max.

3x1000VA

Resolution

Better than 0.01% of full scale value of range

Setting accuracy

Better than 0.05% at the final range value

Stability

Better than 0.005% /h (integration time 150s)

Load regulation from 0~max. load

Better than 0.01%

Distortion factor

Better than 0.3% for linear resistance load

Harmonic

2nd~21st  free programmable

Current

 

Test current output

3x(1mA~100A)

Power of the current output

Max. 3x150VA

Max. 3x350VA

Max. 3x750VA

Max. 3x1500VA

Resolution

Better than 0.01% of full scale value of range

Setting accuracy

Better than 0.05% at the final range value

Stability

Better than 0.005% /h (integration time 150s)

Load regulation from 0~max. load

Better than 0.01%

Distortion factor

Better than 0.3% for linear resistance load

Harmonic

2nd~21st  free programmable

Phase angle

 

Range

0~360⁰

Resolution

0.01⁰

Setting accuracy

0.1⁰

Frequency

 

Range

45Hz~65Hz

Resolution

0.01Hz

Error display

 

Type of error display

Red LED

Resolution of error displays

8 digitals

Other

 

Voltage supply

3x220/380V±10%(or customized)

50/60Hz ±2Hz

Ambient temperature

-10°C~+40°C

Relative humidity

35%~85%

Description: Installing the ICT in each meter position to test three-

Contact Supplier

Mr. John Shen sale Manager Chat Now
Telephone
86-20-87036713
Mobile
86-13609025617
Fax
86-20-87037211
Skype
zhuohan.shen
Address
3/F, Building C2, Kemulang Industry Zone, 98 Guangzhou Er Road, Tianhe District, Guangzhou China Linyi,Shandong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electronic Components & Supplies > Electronic Accessories & Supplies > Semiconductors
Categories
Hi~