PVC fiber & mica compound insulated, metal screened fire-proof control soft cable
Negotiable /Piece
Min.Order:1 Piece
Hebei New Baofeng Wire & Cable Co.,Ltd.
High Quality PVC insulated fixed Laying Cable Wire, Low-voltage Power Cable
Prefabricated Waterproof and Refractory Branch cable, Low-voltage Power Cable
Diameter Expanded Hollow Wire Used for Internal Aerial Electricity For Electric Station
Plastic Insulated Control Special Cable 450 / 750V D.C. Resistance of Conductor at 20
Heat-resistance Fire-proof Cable Special Cable Used for Power Transmission at High Temp
Fire-Proof Wire & Cable Serial Products Suitable For Alarm Fire-control System
The electric property of the product is the same as those common wire and cable, and its properties of fire-resisting conform to the GB/T18380-2001(IEC60332:1993) and GB/T19216.21-2003 the State Standard or the GA306-2007 the Public Safety industrial Standard regulated by the State.
This product is suitable for use in all places using rated AC voltage 1-10kv plastic insulated power cable, 450/750v plastic insulated control cable, 450/750v and below electrical equipment wire and cable, particularly high temperature, inflammable and fire-proof for transmitting and distributing power, control, alarm fire-control system and otter circuits.
1.According to different product kinds, kinds, rated voltage can be divided into the following: a, 0.6/1-8.7/10kv b, 450/750v c, 300/500v d, 300/300v
2.Allowed work temperature of cable for a long period is divided into the following according to different kinds of products: 70℃, 90℃, 105℃.
3. For short circuit(5s), the allowed max. work temperature of conductor does not exceed 160℃ and 250℃(for1-a).
4.Environmental temperature for laying cable should be not less than 0℃.
5.Allowed min .bend radius of cable should be according to different kinds of the following products:6 times, 10 times, 12 times and 15 times of cable overall diameter.
6.Cable combustion nature
a. Under flame temperature 750-800℃ combustion conditions, cable can normally operate not less than 90 min.
b. Measured cable current-carrying capacity under “a” environment is not less than the current-carrying capacity value under work conditions of less than the current-carrying capacity value under work conditions of corresponding type and specifications of common cable.
7.Other electric nature and physical-mechanic nature of cable are all higher than corresponding common cable.
Petroleum, chemical, industry, metallutgy, power plant, transmission substation, high rises, underground railway, telecommunications station, nuclear project, military, aviation, tunnels, high scientific research, fire control, etc.