■ Product standard
The electric property of the product is the same as those common wire and cable, and its properties of fire-resisting conform to the GB/T18380-2001(IEC60332:1993) and GB/T19216.21-2003 the State Standard or the GA306-2007 the Public Safety Industrial Standard regulated by the State.
■ Usage
This product is suitable for use in all places using rated AC voltage 1-10kV plastic insulated power cable, 450/750V plastic insulated control cable, 450/750V and below electrical equipment wire and cable, particularly high temperature, inflammable and fire-proof for transmitting and distributing power, control, alarm fire-control system and other circuits.
■ Property for Use
1. According to different product kinds, rated voltage can be divided into the following:
a,0.6/1-8.7/10kV b,450/750V c,300/500V d,300/300V
2. Allowed work temperature of cable for a long period is divided into the following according to
different kinds of products: 70℃, 90℃, 105℃.
3. For short circuit (5s), the allowed max. work temperature of conductor does not exceed 160℃ and 250℃ (for 1-a).
4. Environmental temperature for laying cable should not be less than 0℃.
5. Allowed min. bend radius of cable should be according to different kinds of the following products: 6 times, 10 times, 12 times and 15 times of cable overall diameter.
6. Cable combustion nature
a. Under flame temperature 750-800℃ combustion conditions, cable can normally operate not less than 90 min.
b. Measured cable current-carrying capacity under “a” environment is not less than the current-carrying capacity
value under work conditions of less than the current-carrying capacity value under work conditions
of corresponding type and specifications of common cable.
7. Other electric nature and physical-mechanic nature of cable are
all higher than corresponding cable.
■ Type of Cable
Type |
Rated Voltage |
Designation |
Scope of Application |
NH-VV NH-VV22 |
0.6/1KV |
PVC fiber, mica & PVC compound insulated fireproof power cable |
Petroleum,chemical,industry, metallurgy,power plant, transmission substation, high rises, underground railway, telecommunications station, nuclear project, military, aviation, tunnels, high scientific research, fire control, etc. |
NH-YJY NH-YJV22 |
8.7/10KV and below |
XLPE or silane XLPE fiber & mica compound insulated fireproof power cable |
|
NH-KVV NH-KVV22 |
450/750V |
PVC fiber & mica compound insulated fire-proof control cable |
|
NH-KVVR |
PVC fiber & mica compound insulated fire-proof control soft cable |
||
NH-KVVP22 NH-KVVRP |
PVC fiber & mica compound insulated, metal screened fire-proof control soft cable |
||
NH-BV |
450/750V |
PVC fiber & mica compound insulated fire-proof wire |
Petroleum, chemical industry, metallurgy, high rises, scientific research and other power and illuminating installation, electric instrument and meters requiring fire-proof. |
NH-BVR |
450/750V |
PVC fiber & mica compound insulated fire-proof soft wire |
|
NH-BVV |
300/500V |
PVC fiber & mica compound fire-proof cable |
|
NH-PVV NH-PVV22 |
250V |
PVC fiber & mica compound insulated fire-proof signal cable |
Railway automatic installations, signal transmission & monitoring fire-proof places. |
NH-PUYV NH-PUYVR |
PE fiber & mica compound insulated fire-proof mine signal(soft) cable |
Mine pit signal transmission & |