Customized 2000L Solar Panel Test Chamber for PV Module Dynamic Testing
Negotiable /Piece
Min.Order:1 Piece
KOMEG Technology Ind Co., Limited
Custom Temperature / Humidity Environmental Test Chamber Burn-in Test Rooms
High Precise Industrial Drying Oven Chamber Painted Exterior Stainless Steel Plate
Environmental Climatic Test Chamber Temperature / Humidity / Salt Spray Test Chamber
High And low Temperature Climatic Test Chamber With Air Cooled 64L - 1CBM
Larger Volume Electroplated SUS304 Walk-in Climatic Test Chamber / Rooms
Custom Stand Alone Programmable Climatic Test Chamber for Laboratory
Customized 2000L Solar Test Chamber for PV Module Dynamic Testing
1. Application:
Solar test chamber is mainly used for reliability test of solar cells in the specification to be verified in wet, frozen, temperature cycle, humidity test etc can be monitored during the experiment the continuity of the internal circuit of solar cells in order to determine whether the fault or failure, by the system solar battery failure can be determined.
2. Features:
Data and Monitoring software
Module surface temp, test Chamber inside temp record and display
Module voltage & current record and display
With real time display curve and of the measured data and can be stored by USB connection
3. Test Model or test project
1). Damp Heat Test:
Test Condition: 95 ±2 ºC temperature range , and 95% ±5% R.H. humidity range
Test Duration: last for 1000H,
Test Purpose: To see the reliability of the module to withstand the effects of long-term penetration of heat and humidity.
2). Humidity-freeze test
Test Purpose: to see the ability of the module to withstand the effects of high temperature and humidity followed by sub-zero temperatures.
Test points and requirements:
-40ºC lowest temperature and 85ºC highest temperature
Max temperature rising speed rate:200ºC/Hour=3.33/min
Max temperature falling speed rate:200ºC/Hour=3.33/min
24 hours per cycle, testing for 10 cycles, 240 hours (10 days)
Temp. Cycle Compare |
High Temp. High Humidity |
Low Temp |
Temp. Change Rate |
Cycle No. |
IEC61215 |
85ºC/85±5%(20h) |
-40ºC(0.5~4h) |
High Temp. Rise& Fall(100ºC/h) |
10 |
GB9535 |
85ºC/85±5%(20h) |
-40ºC(0.5~4h) |
High Temp. Rise& Fall(100ºC/h) |
10 |
IEC61646 |
85ºC/85±5%(20h) |
-40ºC(0.5~4h) |
High Temp. Rise& Fall(100ºC/h) |
10 |
GB18911 |
85ºC/85±5%(20h) |
-40ºC(0.5~4h) |
High Temp. Rise& Fall(100ºC/h) |
10 |
UL1703 |
85ºC/85±2.5%(20h) |
-40ºC(0.5~4h) |
High Temp. Rise& Fall(100ºC/h) |
10 |
IEC62108 |
85ºC/85±2.5%(20h) |
-40ºC(0.5~4h) |
High Temp. Rise& Fall(100ºC/h) |
20 |
3). Thermal cycle test;
Test requirements: -40ºC lowest temperature and 85ºC highest temperature
Temperature falling/rising speed rate:100ºC/Hour=1.67ºC/min,6 hours per cycle,
Test Duration: 50~200 cycles
total testing time last 300 to 1200 hours (12.5 to 50 days)
Temp. Cycle Compare |
Low Temp |
High Temp |
Temp Change RateºC/h |
Dwell Time |
Cycle Number. |
IEC61215 |
-40±2ºC |
85±2ºC |
Max. 100ºC/h |
Min.10min |
50, 200 |
GB9535 |
-40±2ºC |
85±2ºC |
Max.100ºC/h |
Min.10min |
50, 200 |
IEC61646 |
-40±2ºC |
85±2ºC |
Max.100ºC/h |
Min.10min |
50, 200 |
GB18911 |
-40±2ºC |
85±2ºC |
Max.100ºC/h |
Min.10min |
50, 200 |
UL1703 |