Inductive loop vehicle detector for automatic vehicle parking system
Negotiable /Piece
Min.Order:1 Piece
Shenzhen Tenet Technology Co., Ltd
CAN bus Vehicle Parking System for Residential area entry access
Parking guide system indoor Green Red LED parking direction display rs485
High Speed TCP/IP Vehicle Barcode Parking System , Chinese / English supported
Vehicle Parking Barcode Parking System for hospitals / shopping mall
Wireless ultrasonic sensor Parking Lots Guidance System for shopping mall / hotel
Intelligent Parking Lots Guidance System with Electronic Wireless ultrasonic sensors
Vehicle Loop detectors are used wherever vehicles have to be detected such as monitoring and safe guarding access ways or for counting vehicles. The output signal can be used for controlling door and gate drive mechanisms, operating barriers, controlling traffic light systems in car parks or activating card dispensers in car parking lots.Model TLD-110 connects one inductive loop.
Operation and Indication
To eliminate interference of two neighbouring wire loops or loop detectors,
the frequency can be altered by DIP4 on the main board in the box.
The response sensitivity can be set using the threestage switch on the front. The setting “L”
corresponds to the lowest sensitivity. “M” is the medium sensitivity and “H” is the highest
sensitivity.After the sensitivity has been set, a reset and a calibration automatically takes place.
【Attention】 If the detector isn’t working normally, you must check the loop and wiring at first,
and then alter the frequency or the sensitivity.
The output of relay 2 can be programmed by means of DIP3 Switch.
If DIP3 is “OFF” site, the output is presence output. When a vehicle is detected passing over
the inductive loop, the relay 2 is energized( Pin3 and Pin4 is shorted) until the vehicle is detected
leaving the loop. If DIP3 is “ON” site, the output of redlay 2 is same as relay 1.
The output of relay 1 can be programmed by means of DIP1 and DIP2 Switch.
The detector automatically reset and tune to the inductive loop when the power is applied,
whether on initial installation or after any break in power supply. Should it be necessary to retune the
detector, as may be required after changing any of the switches or after moving the detector from one
installation to another.
1. Model TLD-410 with double loops
2. Operating temp.: -20C~ +65C
3. Storage temp.: -40C~ +85C
4. Frequency range: 20 kHZ to 170 kHz,2 grades adjustable
5. Reaction Time:100ms
6. Installation: DIN rail
7. Dimensions: 75×37×110 mm (L×W×H)
8. Net Weight: 400g
9. Operating voltages:AC220V±10%
10. Power consumption: 5W
11. Relay output: DC24V /3A
12.Reaction time: 20 ms
13.Connection: 11-pin socket
14.Sensitivity:Adjustable in 3 increments
15.Loop inductance: Ideal 100µH300µH(include connecting wiring); Max 50µH1000µH(include
connecting wiring)
16.Loop connection wiring:Maximum length 20 meters,twisted at least 20 times per meter
17.Size of Housing:78*40*108mm