Modular Calibration Of 1-Phase Energy Meter With Remotely Update Software
Negotiable /Piece
Min.Order:1 Piece
Automatic 3 - Phase Energy Meter Calibration Equipment With RS232 / RS485
Intelligent type radar liquid level transmitter with non - contact from METERY TECH
waterproof Cable type intelligent radar level transmitter with high accuracy
high performance Intelligent radar liquid level transmitter rod type for grain bin
high frequency Intelligent radar liquid level transmitter for tank / solid / liquid
professional Intelligent radar liquid level transmitters for oil / fuel / water
Modular Calibration Of 1-Phase Energy Meter With Remotely Update Software
Product Profile:
All kinds of active/reactive energy meter can be calibrated.
Main Features:
Automatically or single-step manually test basic error, Creeping, start, standard deviation of single/three phase energy meter, besides, automatically testing can be self-defined by user; Automatic Calibration System can be customized according to customer\'s requirements; Exchange the testing settings and testing records thru U disk(or SD card); Accuracy :U, I, P, Kwh : ±0.05%; Q, Kvarh : ±0.1%; U, I, P stability : 0.01%RG/3min, AC Voltage and AC Current distortion : ≤0.2%; Current scope: Min. 0.05A, Max. 100A(Max output 120A); Voltage 57.7V-380V; Export 2nd-63rd harmonics, and measure & analyze the harmonics; With OCXO daily error of energy meter can be detected; 7\" color touch screen, interface friendly, easy to operate; Equipped with RS232 & Ethernet interface, AT6025C can be operated either stand-alone, or controlled by PC; Remotely updating online, easily achieve software updating; Equipped with barcode gun interface, parameters of tested meters can be easily scanned in; Communicate with tested meters thru RS485, Ethernet, RS232; Self-protection, alarming and displaying overload location for equipment output overload, Voltage short-circuit, Current open-circuit; Self-diagnosis for amplifier failure and internal module communication failure; Test 3 energy meters with the same model type at one time Test energy meters with the accuracy of Class 0.2 and below (Class 0.05 equipment);Technical Specification
Range |
Capacity |
Adjustment Degree |
Adjustment Range |
Stability |
Distortion (linear load) |
Measurement accuracy |
|
AC Voltage |
57.7V~380V |
30VAmax/ phase |
0.01%RG |
0~120%RG |
0.01%RG 3min CL0.05 0.02%RG 3min CL0.1 |
0.2% CL0.05 0.5% CL0.1 |
±0.05%RG CL0.05 ±0.1%RG CL0.1 |
AC Current |
0.05A~120A |
100VAmax/ phase @100A |
0.01%RG |
0~120%RG |
0.01%RG 3min CL0.05 0.02%RG 3min CL0.1 |
0.2% CL0.05 0.5% CL0.1 |
±0.05%RG CL0.05 ±0.1%RG CL0.1 |
Phase |
0.00°~359.99° |
0.01° |
0.00°-359.99° |
0.01° |
±0.05° |
||
Frequency |
40Hz ~70Hz |
0.002Hz |
40Hz -70Hz |
0.002Hz |
±0.003Hz |
||
Power/Energy |
±0.05%RG CL0.05 ±0.1%RG CL0.1 pf≥0.5 |
||||||
Output Harmonics |
2nd to 63rd |
0.01%RG |