Industry 5300 Series Rosemount Level Transmitter for submerged interface

Industry 5300 Series Rosemount Level Transmitter for submerged interface

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
0 Piece / Pieces per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Rosemount
Place of Origin:
China
Model Number:
5300

Beijing Zhongzhiguochuang Automation Equipment Co.,ltd

Business Type: Trading Company
Main Products:

Product Details

Delivery Time:2~4weeks
Certification:CSA Explosion-proof FM Explosion-proof, Dust Ignition-proof ATEX Flame-proof

5300 Series Rosemount Level Transmitter for level of liquids or submerged interfaces , interface liquids , solids

Quick Detail:

· 5301 for level of liquids or submerged interfaces

· 5302 for level and interface liquids

· 5303 for level of solids

· Time domain reflectometry (TDR) measurement principle

· SST, Monel, Hastelloy or PTFE-covered SST probe materials

· 4-20mA with superimposed HART or Fieldbus communication output

· Up to 752°F process temperature

· Up to 5000 psi (345 bar) process pressure at 100°F

· Intrinsic safety or Explosion/Flameproof Ex-Approvals

Description:

The Rosemount 5300 Series level transmitter is our premium 2-wire guided wave radar for challenging level and interface measurements on liquids, slurries and solids. The Rosemount 5300 Series level transmitter delivers everything you would expect from a best-in-class process radar - superior reliability, state-of-the-art safety features, effortless handling, and unlimited connectivity.

Guided Wave Radar is a continuous level measurement technique that offers several advantages. It is virtually unaffected by temperature, pressure, and vapor gas mixtures. It has no moving parts and therefore requires little or no maintenance. It measures the level directly and is therefore unaffected by most fluid property changes, including but not limited to density and viscosity changes.

The Rosemount 5300 Series level transmitter is based on the Time Domain Reflectometry (TDR) technology. Low power nano-second microwave pulses are guided down a probe submerged in the process media. When a radar pulse reaches a media with a different dielectric constant, part of the energy is reflected to the transmitter. The time difference between the transmitted and the reflected pulse is converted into a distance from which the total level or interface level is calculated.

The Rosemount 5300 Series level transmitter delivers cutting edge performance with DST, which is a rapid switch for signal transmission between the transmitter and the receiver. The Rosemount 5300 Series level transmitter minimizes signal losses, which results in a two to five times stronger received signal compared to other guided wave radar transmitters. This results in a better signal-to-noise ratio and an increased ability to handle disturbing factors. It also enables long measuring ranges (up to 164 ft (50m)) and measurements on low reflective media (dielectrics from 1.4), even with a single lead probe.

The Rosemount 5300 Series level transmitter has a dual compartment head to separate electronics from cable connection. Featuring easy-to-access and robust cable terminals and an optional easy-to-read display, the Rosemount 5300 Series level transmitter head can be rotated 360° and is removable while the tank is in service. There is no matching between head and probes. All of this adds up to reduced cost and increased safety.

Probes are available in different styles and materials, also with options to handle extreme pressure and temperature. Rosemount Radar Master ™ with its user-friendly interface is the ultimate setup and troubleshooting software. The Rosemount 5300 Series level transmitter powers the PlantWeb architecture by delivering the best Multivariable ™ transmitter (both level and interface from the same 2-wire unit), the best installation practices, and the best field intelligence with advanced diagnostics for HART ® and FOUNDATION ™ fieldbus. This enables proactive maintenance for increased process availability.

The Rosemount 5300 Series level transmitter uses the same two wires for both power supply and communication. Measurement data is transmitted as an analog 4-20 mA signal with a superimposed digital HART ® signal or FOUNDATION ™ fieldbus signal. The HART ® signal can be used in a multidrop mode. By sending the digital HART ® signal to the optional HART ® Tri-loop, it is possible to have up to three additional 4-20mA analog signals.

Applications:

The Rosemount 5300 Series level transmitter is our premium 2-wire guided wave radar for challenging level and interface measurements on liquids, slurries and solids. The Rosemount 5300 Series level transmitter delivers everything you would expect from a best-in-class process radar - superior reliability, state-of-the-art safety features, effortless handling, and unlimited connectivity.

Specifications:

Rosemount 5300 series radar transmitter
Product Model 5301 for level of liquids or submerged interfaces. Model 5302 for level and interface in liquids. Model 5303 for level of solids.
Measurement Principle Time Domain Reflectometry (TDR)

Contact Supplier

Ms. Shouyan Huo sale Manager Chat Now
Telephone
86-10-52900365
Mobile
86-18600678435
Fax
86-10-82561707
Skype
huoshouyan678
Address
Room 805, Building 6, No. 5 Changchunqiao Road Weinan,Shaanxi

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Service Equipment > Restaurant & Hotel Supplies > Hotel Amenities
Categories
Hi~