fixe H2S detect monitor
Negotiable /Unit
Min.Order:1 Unit
Henan Chicheng Electronics Co.,Ltd
Characteristics:
◆Sensor types:electrochemical sensor
◆4-20mA analog output(3+ channel) for direct communication to DCS system and RS485 ModBusoutput
◆Sensormodule design on -spot replacement s and automatically distinguish sensor fault and current display fault simultaneously.
◆LED Display(LCD optional)
◆Password verification for repeat operation, avoid fault operations.
◆-40~+70℃ following compensationfor accurate detecting.
◆Second grade visual alarms on-site and Relay(connected with audible/visual alarms or drive exhaust device).
◆User-selectable alarm setpoint(s).
Environment Parameter |
Environment temperature:-20℃~+60℃ |
Relative humidity ≤90%R.H. |
|
Technical Parameters |
Working voltage: 16~30VDC |
Working current: QB-01T is 120mA, others ≤50 mA |
|
Output signal: 4~20mA standard signal two wire type output (QB-01T three wire type) |
|
Sensor |
electrochemical sensor; QB-01T is catalytic combustion type |
Respond Time |
T90 less than 30 seconds |
Exterior Structure |
Weight ≤900g |
Mounting |
type: wall-mounted |
Transition cable: two core shield cable (QB-01T uses three core shield cable), section 2×1.5mm2, external diameter Ā10mm |
|
Transferring distant ≤1000m |
|
Anti-explosion Class |
Exd IICT6(used for explosion proofing);ExiaIICT4(used for intrinsic safety type) |
Ingress Protection |
IP66 |