cat6 ftp lan cable
Negotiable /Piece
Min.Order:1000 Pieces
Shenzhen CCB Technology Co., Ltd.
Meets TIA/EIA/ 568-B.2 requirements Fire protection - CM The cable meets UL 444 UL 1581 fire safety standard |
Shielded Copper cable, 4 pairs (separated), category 6, solid, with drain wire Application: Horizontal communication cable Cable is used for indoor installation |
Conductive material: wire made of annealed bare copper Conductor insulation: HDPE Shield: an aluminum-mylar (aluminum-polyethyleneterephthalate) tape is helically applied over the cable core, tape thickness - 0.001" (0.025 mm), width - 0.709" (18 mm); shield thickness - 0.016" (0.04 mm) Drain wire: tinned copper The cable jacket: PVC |
Conductor diameter: 0.57 mm (0.022") (23 AWG) Insulated conductor diameter: 1.09 +- 0.06 mm (0.043" +- 0.002") Drain wire diameter: 0.53 mm (0.021") Outer cable diameter: 7.2 +- 0.3 mm (0.276" +-0.012") Jacket thickness: 0.55 mm (0.028") Shield thickness: 0.04 mm (0.016") Minimum bend radius: 8 outer cable diameters Conductor elongation: 15% minimum Operating temperature: -20 - +75 (-4F - +167F) Rip cord has a breaking strength of 6.9 kg (60 N) Standard package: 305 m (1000.66 ft) Weight per 1000 ft (304.8 m): 16.8 kg (37.04 lbs) |
Frequency, MHz | RL | Attenuation, dB | NEXT, dB | PSNEXT, dB | ELFEXT, dB | PSELFEXT, dB |
---|---|---|---|---|---|---|
1.0 | 20.0 | 1.9 | 74.3 | 72.3 | 67.8 | 64.8 |
4.0 | 23.0 | 3.7 | 65.3 | 63.3 | 61.8 | 52.8 |
8.0 | 24.5 | 5.3 | 60.3 | 58.8 | 55.7 | 46.7 |
10.0 | 25.0 | 5.9 | 59.3 | 57.3 | 53.8 | 44.8 |
16.0 | 25.0 | 7.5 | 56.3 | 54.3 | 49.7 | 40.7 |
20.0 | 25.0 | 8.4 | 54.8 | 52.8 | 47.8 | 38.7 |
25.0 | 24.3 | 9.5 | 53.4 | 51.4 | 45.8 | 36.8 |
31.25 | 23.6 | 10.6 | 51.9 | 49.9 | 43.9 | 34.9 |
62.5 | 21.5 | 15.4 | 47.4 | 45.4 | 37.9 | 28.8 |
100.0 | 20.1 | 19.8 | 44.3 | 42.3 | 33.8 | 24.8 |
155.00 | 18.8 | 25.1 | 41.4 | 39.4 | 27.8 | 20.9 |
200.00 | 18.0 | 29.0 | 39.8 | 37.8 | 25.8 | 18.7 |
250.00 | 17.3 | 32.8 | 38.3 | 36.6 | 24.3 | 16.8 |
Max conductor resistance at 20°C (68°F) | 9.38 Ohm/100 m (2.86 Ohm/100 ft) |
Max Resistance Unbalance | 5% |
Max pair-to-ground capacitance unbalance | 330 pF/100 m (101 pF/100 ft) |
Characteristic Impedance at 0.772-100 MHz | 100 +- 15 Ohm |
Mutual capacitance | 5.6 nF/m (1.7 nF/ft) |
Spark Test | 2.5 kV |