Twisted Pair Cable (UTP), 4 pairs, Category 6, Patch, PVC
USD $0.1 - $0.9 /Piece
Min.Order:1000 Pieces
Shenzhen CCB Technology Co., Ltd.
Meets ANSI/EIA/TIA 568-B.2-1 requirements Fire protection – CM The cable meets UL 1581 VW-1 fire safety standard |
Unshielded Copper cable, 4 pairs, category 6, stranded (patch) Cable is used for indoor installation |
Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE, film-porous-film structure The cable jacket: PVC |
Conductor diameter: 7 x 0.2 mm ± 0.01 mm (7" x 0.008" ± 0.004") (24 AWG) Insulated conductor diameter: 1.03 ± 0.2 mm (0.04 " ± 0.008") Outer cable diameter: 5.3 ± 0.2 mm (0.2" ± 0.008") Jacket thickness: 0.4 mm (0.015") Minimum bend radius: 4 outer cable diameters Operating temperature: -5°C – +60°C (+23°F – +140°F) Weight per 1000 ft (304.8 m): 13.7 kg (30.2 lbs) Standard package: 305 m (1000 ft) |
Frequency, MHz | RL | Attenuation, dB | NEXT, dB | PSNEXT, dB | ELFEXT, dB | PSELFEXT, dB |
---|---|---|---|---|---|---|
1.0 | 20.0 | 2.4 | 74.3 | 72.3 | 67.8 | 64.8 |
4.0 | 23.0 | 4.5 | 65.3 | 63.3 | 55.8 | 52.8 |
8.0 | 24.5 | 6.4 | 60.8 | 58.8 | 49.7 | 46.7 |
10.0 | 25.0 | 7.1 | 59.3 | 57.3 | 47.8 | 44.8 |
16.0 | 25.0 | 9.1 | 56.2 | 54.2 | 43.7 | 40.7 |
20.0 | 25.0 | 10.2 | 54.8 | 52.8 | 41.8 | 38.8 |
25.0 | 24.2 | 11.4 | 53.3 | 51.3 | 39.8 | 36.8 |
31.25 | 23.3 | 12.8 | 51.9 | 49.9 | 37.9 | 34.9 |
62.5 | 20.7 | 18.5 | 47.4 | 45.4 | 31.9 | 28.9 |
100.0 | 19.0 | 23.8 | 44.3 | 42.3 | 27.8 | 24.8 |
200.0 | 16.4 | 34.8 | 39.8 | 37.8 | 21.8 | 18.8 |
250.0 | 15.6 | 39.4 | 38.3 | 36.3 | 19.8 | 16.8 |
Conductor resistance at 20°C (68°F) | 9.38 Ohm/100 m (2.9 Ohm/100 ft) |
DC Resistance Unbalance | 5% |
Pair-to-Ground Capacitance Unbalance | 330 pF/100 m (101 pF/100 ft) |
Impedance 0.772-100 MHz | 85-115 Ohm |
Mutual Capacitance | 5.6 nF/m (1.7 nF/ft) |
Spark Test | 2.5 kV |