Secondary Injection Protection Relay Test Set K3040

Secondary Injection Protection Relay Test Set K3040

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
0 Piece / Pieces per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Kingsine
Place of Origin:
China
Model Number:
K3040

Kingsine Electric Automation Co., Ltd.

Business Type: Trading Company
Main Products: Protection Relay Testing ,Relay Test Set ,Relay Test System

Product Details

Delivery Time:15 working days
Certification:ISO9001,CE

1. Unique self-protection system assure the powerful protection when instrument is operating, automatic stop the output when the network is abnormal ;
2. Unique power switch and amplifier technology, so the output precision and power efficiency and factor are increased, which conforms to international tendency of energy save and environmental protection;
3. With alarm function of housing grounding testing and external voltage input, to guaranty personal security;
4. Two in one of meter and source, with function of both internal and external testing, self-calibration, oscillograph, and the duration of each oscillograph reaches 50S (optional function);
5. Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A (Poleless and adjustable);
6. Function of transducer and energy meter testing (optional function);
7. Testing interface offer unique output monitoring function and Pre-curve-tracing function, helps more on the spot analysis;

Technical Data of K3040

Voltage generators

Setting 

Range

4-phase AC (L-N)

4 x 0 ... 130 V 

2-phase AC (L-L)

2 x 0 ... 260 V

Power

4-phase AC (L-N)

4 x 70VA,  at 0 ... 130 V

2-phase AC (L-L)

2 x 140VA,  at 0 ...260 V

Accuracy

<0.07% reading + 0.03% range guaranteed 

at 0 ... 130 V

<0.02% reading + 0.01% range typical 

at 0-130V

Resolution

1mV

Current generators

Setting 

Range

3-phase AC (L-N)

3 x 0 ... 40 A

1-phase AC (2L-N)

1 x 0 ... 80 A 

1-phase AC (3L-N)

1 x 0 ... 120 A 

Power

3-phase AC (L-N)

3x 450VA , at 0 ... 40A 

1-phase AC (2L-N)

1x 520VA,  at 0 ... 80A 

1-phase AC (3L-N)

1 x 1200 VA,  at 0 ... 120A (Max.)

Accuracy

<0.07% reading + 0.06% range guaranteed at 0-40A 

<0.02% reading + 0.02% range typical at 0-40A

Resolution

1mA

Generators,  general

Frequency

Range

0 ... 1000 Hz

Accuracy / drift

Error < 0.001Hz at 10 ... 65Hz,

Error < 0.01Hz  at 65Hz...450Hz

Error < 0.02Hz  at 450Hz...1000Hz

Resolution

0.001Hz

Phase

Range

- 360° ... +360°

Accuracy / drift

Error < 0.2 °

Resolution

0.1°

Timer

Range

Infinite

Accuracy / drift

Error<0.1ms

DC generators

Contact Supplier

Ms.Vicky Contact Person Chat Now
Telephone
86-755-83418941
Mobile
86-83418941
Fax
86-755-88352611
Skype
kingsine_internation
Address
6/F, Block 4-CD, TianAn Cyber Park,Shenzhen 518048,.China Dezhou,Shandong