EJA430E Traditional-mount Gauge Pressure Transmitter
USD $550 - $600 /Piece
Min.Order:1 Piece
Dekemeng Process Control (Wuhan) Co.,Ltd.
EJA430E Traditional-mount Gauge Pressure Transmitter
Introduction
The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family of pressure transmitters. Released in 2012, it combines the ruggedness and success of the work-horse EJA-A series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.
The EJA430E is traditional-mount gauge pressure transmitter in the series.
Features :
± 0.055% Accuracy (0.04% Accuracy optional)
± 0.1% Stability per 10 years
90 ms Response Time
Exida and TUV SIL 2/3 Certified
Local Parameter Setting (LPS)
Output:
Output:
D 4 to 20 mA DC with digital communication (BRAIN protocol)
J 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)
F Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN)
G Digital communication (PROFIBUS PA protocol, refer to GS 01C31T04-01EN)
Q Low Power, 1 to 5 V DC with digital communication (HART 7 protocol)
Measurement Span (Capsule):
Capsule H
5~500kPa
Capsule A
0.03~3.5MPa
Capsule B
0.14~16MPa
Power Supply:
10.5~42V DC
Process Connections :
0 without process connector (Rc1/4 female on the cover flanges)
1 with Rc1/4 female process connector
2 with Rc1/2 female process connector
3 with 1/4 NPT female process connector
4 with 1/2 NPT female process connector
5 without process connector (1/4 NPT female on the cover flanges)
Amplifier Housing
1: Cast aluminum alloy
2: ASTM CF-8M stainless steel
3: Cast aluminum alloy with corrosion resistance properties
Electrical Connection
0 G1/2 female, one electrical connection without blind plugs
2 1/2 NPT female, two electrical connections without blind plugs
4 M20 female, two electrical connections without blind plugs
5 G1/2 female, two electrical connections and a blind plug*7
7 1/2 NPT female, two electrical connections and a blind plug*7
9 M20 female, two electrical connections and a blind plug*7
A G1/2 female, two electrical connections and a SUS316 blind plug
C 1/2 NPT female, two electrical connections and a SUS316 blind plug
D M20 female, two electrical connections and a SUS316 blind plug
Integral Indicator
D Digital indicator
E Digital indicator with the range setting switch (push button)*9
N None