reci brand power supply for recei tube 80w 100w 130w 150w
USD $1 - $250 /Set
Min.Order:1 Set
Shenzhen Reliable Electromechanical Technology Co., Ltd.
Reci Power Supply DY10
for W2 Z2 S2 80w 90w reci co2 laser tube
Reci Power Supply DY13
for W4 Z4 S4 100w reci co2 laser tube
Reci Power Supply DY20
for W6W8 S6 S8 130W-150W reci co2 laser tube
1.high effeciency
tection system
3.good performance
4.10000 hours working time
Warranty: 1year
Mark & model :
HY-DY10 DY13 DY20 are featured as small size, quick response, which is suitable for Reci W2 & Z2 w4 z4 w6 z6 w8 z8 laser tube
Co2 power supply type | Warranty time | Match laser tube |
DY10 | One year | Z2 &W2 |
DY13 | One year | Z4 &W4 |
DY20 | One year | Z6 Z8 &W6 Z8 |
Main Feature
1.The shape of this power supply is thin which is specially designed for special laser tube. The power supply makes laser tube output larger and more stable.
2. Quick Response: It can enlarge laser power and prolong laser tube’s service life.
3. Easy Control: The start and stop of laser can be easily controlled by TTL level.
4. This power supply has output open circuit protection.
5. This power supply has TTL signal indication, water Through signal indication and laser output indication.
6.This power supply has the BUTTON to test it work properly.
Technical Parameter
item |
| HY-DY10 | HY -DY13 | HY-DY20 | |||||
Input | Input Voltage | AC220VorAC110V( The order should be especially instructions ) | |||||||
AC Frequency | 47---440Hz | ||||||||
Max Input Power | 450W | 550W | 1000W | ||||||
Max Input current | 5A | 8A | 10A | ||||||
Output | Max output Voltage | 35KV | 40KV | 50KV | |||||
Max Output current | 24mA | 28mA | 35mA | ||||||
Efficiency | equal or more than 90percent ( load down ) | ||||||||
Time no-failure | equal or more than10000h | ||||||||
Response speed | equal or less than 1mS( the time from output of switch signal to 90 percent of initial setting current ) | ||||||||
Voltage-resisting | Input-Output ,input-machine hull :AC1500V 10mA 60s; output cathode and machine hull connection | ||||||||
Usage environment | Work temperature (-10~40) , Relative humidity :equal or less than 90percent | ||||||||
Cooling Type | The force air cooling | ||||||||
Dimension (W*H*D)mm |
| 175*155*78 | 247*161*78 | 290*200*79 |
Power Supply Instruction
I. Instruction for sub-connection wire of the control end
1 2 3 4 5 6 5V TH TL WP G IN |
1) Footer 1 is 5V power supply. (Not needed when connecting the cardinal plate. It is used when regulating
the power with potentiometer, and the 5V current should be less than 10 mA.
2) TH. TL refers to high and low power level respectively, and WP refers to water
protection.
3) Footer 5 G refers to ground, and 6 refers to input end.
4) When connecting the control plate, connect the light signal with footer2 in
5) PWM can also be used in footer 6, but the pulse peak is required to reach 5V, and the frequency should be above 20K.
6) For testing: 3, 4 and 5 are in short circuit (or 4, 5 are in short circuit and 3,
5 are connected to switch), the potentiometer center is connected with 6 IN, and
the two other ends are connected to 5V and ground (1 and 5) respectively.
7) The high power level controls the light, 1 and 2 are connected, and 4 and 5 are in
water protection.
8) It is not proposed to control laser power with high
frequency modulation, because it will have impact on the service life of the
laser.
9) The model is applicable to W4 laser, it is necessary to regulate and use the
current according to the laser instructions.
II.Instruction for power wire
Footer 1 Ground | footer 2 footer3 AC 220V 50HZ 10A |
Note: The table 10A refers to the connection wire requirement, but not the actual power dissipation.
III. Instruction for laser connection wire
1) The positive red-line with high voltage is connected to the laser tail
2) The negative white-line is connected to laser output window
IV. Current limitation
To limit the working current, the potentiometer (lies in the underside of the power supply) should be rotated in counterclockwise (please refer to the schematic diagram in our website: ). Limit the maximum output current as it is regulated in the operating instruction. The working current should be limited before delivery.
V. Linear scale between input signal and the output current
Turn around the potentiometer, the linear scale will be changed: for example, when the input signal is 0-5V, the output current is 0-40mA.Or when the input signal is 0-2V, the output signal is 0-40mA.
Note: when the potentiometer is turned down too much, the real output current will be brought down by the same input signal.
VI. Using current
The use standard for our power supply is under 220V, 50Hz. The fluctuation of the input voltage and frequency will affect the working current provided by the power supply, the effection is linear relative. The unstable of the input voltage will affect the output power of the laser tube. The fluctuation of the input voltage has no effection on the lifespan of the laser if only the current provided by the power supply is not over the current limitation.
Packikng
All Laser power will be packed in Carton box avoiding to be damaged during the shipping and we will make sure the best and high-quality products for you.
Shipping Policy
1.1.generally, All the items are only shipped after full payment is cleared ,we deliver the parcel in 2~4days after your payment online ,
2.2.We will deliver the parcel by other Express in case quoted Express can’t reach your shipping address.
3.We will ship to the address which you leave in Aliexpress , when you want to change address ,please inform us before the shipment , otherwise we are not responsible for wrong or undeliverable address