CE Certification 70% above efficiency heat exchanger, heat exchange equipment
USD $494 - $494 /Piece
Min.Order:20 Pieces
Xiamen AIR-ERV Technology Co., Ltd.
General informations:
Name:CE Certification 70% above efficiency heat exchanger, heat exchange equipment
Air flow(CFM):50~10200
Power(V):220V/50HZ
Motor:AC motor standard,DC motor optional
Filter:Hepa or F3 filter
Heat exchanger core:Crossflow paper total heat exchanger
Efficient above 70%
Warranty:above 18 month
Main Feature
CE Certification 70% above efficiency heat exchanger, heat exchange equipment
Total heat recovery with temperature and humidity
High efficiency counter flow recuperator
Galvanized steel panel with high strength
High efficiency motor, low noise
Compact design
Bypass is optional
Pre heating is optional
Co2 detector is optional
Sensible heat recovery unit is optional
/D is for DC motor unit
odel | Air Volume (m3/h) | Static Pressure (Pa) | Rated Voltage | Input Power (W) | Summer | Winter | Noise [dB(A)] | Dimension(mm) | Re. weight (kg) | ||||||||||
Temperature Efficiency (%) | Enthalpy Efficiency (%) | Temperature Efficiency (%) | Enthalpy Efficiency (%) | ||||||||||||||||
High | Low | High | Low | High | Low | High | Low | High | Low | High | Low | High | Low | High | Low | ||||
K-02DT | 200 | 100 | 75 | 80 | 220V/50Hz-60Hz | 65 | 70 | 76 | 75 | 59 | 58 | 76 | 75 | 69 | 69 | 30 | 28 | 665×580×268 | 26 |
K-03DT | 300 | 250 | 85 | 75 | 220V/50Hz-60Hz | 107 | 78 | 76 | 77 | 56 | 60 | 76 | 77 | 67 | 70 | 30 | 25 | 745×600×268 | 32 |
K-04DT | 400 | 350 | 90 | 80 | 220V/50Hz-60Hz | 142 | 121 | 76 | 77 | 54 | 58 | 76 | 77 | 66 | 68 | 32 | 26 | 745×800×268 | 38 |
K-06DT | 600 | 500 | 100 | 90 | 220V/50Hz-60Hz | 190 | 162 | 70 | 72 | 50 | 53 | 70 | 72 | 61 | 64 | 33 | 31 | 820*900*268 | 48 |
K-08DT | 800 | 700 | 120 | 100 | 220V/50Hz-60Hz | 320 | 302 | 73 | 75 | 50 | 55 | 73 | 75 | 64 | 69 | 34 | 30 | 1110×880×388 | 73 |
K-10DT | 1000 | 900 | 100 | 80 | 220V/50Hz-60Hz | 410 | 360 | 74 | 77 | 54 | 58 | 74 | 77 | 66 | 70 | 36 | 32 | 1110×1135×388 | 92 |
K-16DT | 1600 | 1400 | 150 | 130 | 220V/50Hz | 815 | 750 | 75 | 77 | 57 | 59 | 75 | 77 | 65 | 68 | 42 | 38 | 1350*1220*437 | 95 |
K-20DT | 2000 | 1800 | 200 | 170 | 220V/50Hz | 980 | 945 | 76 | 78 | 59 | 61 | 76 | 78 | 66 | 68 | 44 | 40 | 1450*1220*500 | 110 |
K-22DT | 2200 | 1600 | 100 | 210 | 1580 | 1260 | 74 | 77 | 56 | 59 | 74 | 77 | 62 | 67 | 56 | 50 | 1500X1330X500 | 133 | |
K-16D | 1600 | 150 | 380V/50Hz | 650 | 75 | 57 | 75 | 65 | 43 | 1350*1220*437 | 98 | ||||||||
K-20D | 2000 | 150 | 380V/50Hz | 1013 | 76 | 59 | 76 | 68 | 45 | 1450*1220*500 | 125 | ||||||||
K-25D | 2500 | 110 | 380V/50Hz | 1875 | 72 | 54 | 72 | 65 | 50 | 1550×1330×548 | 146 | ||||||||
K-30D | 3000 | 60 | 380V/50Hz | 1525 | 75 | 58 | 75 | 68 | 55 | 1550*1330*548 | 165 | ||||||||
K-35D | 3500 | 100 | 380V/50Hz | 2245 | 76 | 58 | 76 | 68 | 55 | 1630*1600*548 | 210 |
Model | Ventilation core | Function | Heat |
KRV | Be made of antiseptic,antimicrobial fibrous Paper and ABS Framework | Recovery heat energy | Total Heat |
The working principle of heat recovery ventilation system is to exchange energy in the air in a two-way exchange system by using heat differences of the inside and outside temperatures. It has several functions; as well as heat recovery it functions as a heat-conductor.
The output of the extractor unit utilises energy from the intake air via an effective heat exchanger
to contribute to reducing the buildings energy requirement. Energy-saving rates of up to 75% can
be achieved with a HRV heat recovery system.
Advantages:
1> Different capacity units provide easy and flexible solutions for rooms of all sizes
2> Consistent performance over long periods of operation
3> A side air flow design largely increases the life expectancy of the heat exchanger
4> Easy maintenance - only the filter needs maintenance.
5> Low noise. Fire foam Fan volute, completely sound-absorbing, less noise, higher heat efficiency.
6> 3 speed air volume control, high, medium, low 3 speed to adjust the air volume.
7> New high-dormant-pressure with two-way air inlet centrifugal turbine. The units are now equiped with new and improved fan
blades giving the heat recovery unit has a larger deflection diameter. As a result, when air flows, the dormant pressure is increased
and the noise is reduced. High dormant pressure and low noise are reliable and perfect for air conditioning designs.
8> High quality special fibrous paper core,with high moisture permeability,good air-tightness,anti-rends,
aging resistance,anti-mildew.
Installation Show: CE Certification 70% above efficiency heat exchanger, heat exchange equipment
We care about all the details in the product process.
As Heat exchange equipments has the soft character to cause the easy deformation, we focus on the safe packing in different transportation way.
Full container | PVC bag + strong carton (pallet for option) |
LCL | PVC bag + special strong carton + pallet |
By air / courier | PVC bag + carboard inserted in carton + special strong carton |
Introduce of AIR-ERV
AIR-ERV in China is the professional manufacturer of Total energy exchanger manufacturersand heat products.
Founded in 1996,we have 20 years of experience.
1. AIR-ERV can supply OEM service for customers.
2. Produce ERV/HRV, heat exchanger according to customer's special demands.
3. Supply spare parts according to order quantity.
4. General testing and operational test carried out for every units before delivery.
5. Long warranty period.
Who Need HRV?
Every home (new and old) needs ventilation to bring in fresh air, to remove stale air, and provide moisture control.
Why HRV?
HRV introduces fresh air to a building and improves climate control, whilst promoting efficient energy use.
While opening a window does provide ventilation, the building's heat and humidity will then be lost in the winter and gained in the summer, both of which are undesirable for the indoor climate and for energy efficiency, since the building's HVAC systems must compensate.
Welcome to visit our CE Certification 70% above efficiency heat exchanger, heat exchange equipment.