Guided radar measurement Time-of-Flight Levelflex FMP52
Negotiable /Piece
Min.Order:1 Piece
Xian Wellwork Industrial Co., Ltd.
Guided radar measurement Time-of-Flight Levelflex FMP52
Coated probe for use in aggressive liquids
Product Overview
Levelflex FMP52 for level measurement in aggressive liquids with chemically resistant gap-free PTFE-coated probe. All wetted parts are FDA listed materials. FMP52 guided radar offers maximum reliability even in case of moved surface. Levelflex FMP52 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Reliable measurement even for changing product and process conditions
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
Highest reliability due to new Multi-Echo Tracking evaluation
Hardware and software developed according to IEC 61508 up to SIL3
Seamless integration into control or asset management systems
Intuitive, menu-guided operation concept (on-site or via the control system) in national languages reduces costs for training, maintenance and operation
World's easiest proof test for SIL and WHG saves time and costs
Version with rod or rope probe.
Process connections: Flange or process connections for hygiene requirements (Tri-Clamp, 11851)
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 4m (13ft), rope 45m (148ft)
Accuracy: Rod probe ±2mm (0.08")
International explosion protection certificates, 5-point linearity protocol, WHG overfill prevention, SIL, EN10204-3.1, 3-A, ship building approval
Measuring Principle | Guided radar | |
Characteristic / Application | Premium device coated for corrosive media Rod probe, Rope probe Wetted parts FDA listed materials, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias. | |
Interface measurement | Clean interfaces liquid/ liquid; Simultaneous measurement of interface and overall level | |
Supply / Communication | 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART) | |
Accuracy | Rod probe :+/- 2 mm (0.08 in) Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in) Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in) | |
Ambient temperature | -40...+80 °C (-40...+176 °F) | |
Process temperature | –50...+200 °C (–58...+392 °F) | |
Process pressure absolute / max. overpressure limit | Vacuum...40 bar (Vacuum...580 psi) | |
Main wetted parts | Rod probe: 304, 304L, 316L, PTFE, PFA Rope probe: 304, 304L, 316, 316L, PTFE, PFA | |
Process connection | Flange: ASME 1 1/2"...6", DN50...DN100, JIS 10K | |
Process connection hygienic | Tri-Clamp DIN11851 | |
Sensor length | Rod probe: 4 m (13 ft) Rope probe: 45 m (148 ft) | |
Max. measurement distance | Rod: 4 m (13 ft) Min DK>1.6 Rope: 25 m...30 m (82 ft...98 ft) Min DK>1.6; 30 m...45 m (98 ft...148 ft) Min DK>1,9 | |
Output | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus | |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IECEx, NEPSI, KC, INMETRO Overfill prevention WHG SIL EN10204-3.1 3A Marine | |
Options | Sensor remote with 3 m/9 ft cable Gas-tight feed through | |
Application limits | High process temperatures (> 150 °C/302 °F) can favor diffusion of the process medium into the probe coating which may lead to a limited lifetime. FMP54 Interface measurement: Use coax system in favor (coax probe, bypass, stilling well) Interface with emulsion: FMP55 |