Endress Hauser Liquid Level Transmitter
Negotiable /Piece
Min.Order:1 Piece
Xian Wellwork Industrial Co., Ltd.
High Quality E+H Ultrasonic Level Transmitter Prosonic M FMU42
Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials.
Quick and simple commissioning via menu-guided onsite operation with four-line plain text display; 7 languages selectable
Envelope curves on the on-site display for simple diagnosis
Easy remote operation, diagnosis and measuring point documentation with the supplied FieldCare operating program
Suitable for explosion hazardous areas (Gas-Ex, Dust-Ex)
Linearisation function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate
Non-contact measurement method minimizes service requirements
optional remote display and operation (up to 20 m (66 ft) from transmitter)
Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
Continuous, non-contact level measurement in fluids, pastes, sullages and coarse bulk materials
Flow measurement in open channels and measuring weirs
System integration via:
HART (standard), 4 ... 20 mA
PROFIBUS PA
FOUNDATION Fieldbus
Maximum measuring range:
10 m in fluids
5 m in bulk materials
For other measuring ranges:
Measuring Principle | Ultrasonic | |
Characteristic / Application | Compact ultrasonic transmitter | |
Supply / Communication | 2/4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus | |
Accuracy | +/- 4 mm or +/- 0,2 % of set measuring range | |
Ambient temperature | -40 °C ... 80 °C (-40 °F ... 176 °F) | |
Process temperature | -40 °C ... 80 °C (-40 °F ... 176 °F) | |
Process pressure absolute / max. overpressure limit | 0.7 bar ... 2.5 bar abs (10 psi ... 36 psi) | |
Main wetted parts | PVDF | |
Process connection | Flange DN80, ANSI 3", JIS 10K 80 DN100,ANSI 4", JIS 10K 100 Mounting bracket | |
Blocking distance | 0.4 m (1.3 ft) | |
Max. measurement distance | 10 m (33 ft) | |
Output | 4 ... 20 mA HART PROFIBUS PA FOUNDATION Fieldbus | |
Certificates / Approvals | ATEX FM CSA NEPSI | |
Application limits | Foam / high turbulence possible: FMU44/FDU92 Fast filling and discharging rate: FMU90 + FDU9x Level limit detection FMU90 + FDU9x |