2012 newest air conditioning thermostat
USD $1 - $2 /Piece
Min.Order:10 Pieces
Tongdy Sensing Technology Corporation (Beijing)
air conditioning thermostat Features
Designedfor control a 3-speed fan and one or two water valves with fan speed auto ormanual adjustment selectable.
LCD displays working status such asroom temperature, set point, fan speed, etc. Makes reading and operating easyand accurate.
All models feature user-friendly setting buttons
Large set point range, the min.and max. limit of temperature presetting by end users
Lowtemperature protection
Celsius or Fahrenheit degreeselectable
Upto 5amp relay outputs to control a 3-speed fan
Key-Cardfunction is used for hotels to keep on
saving-energytemperature in non-occupancy and return back the set point in occupancy.
Infrared Remote Control (optional)
Blue backlight (optional)
RS485 communication interface (optional)
For the FCU systems with aProportional-Action water valve, please see the F2000PS-A series thermostats
Power supply | 230VAC±10% or 110VAC±10%, 50/60HZ |
Electrical rating | F2000LB-S: 2 amp maximum load for 3 speed fan F2000PS/PSC series: 5 amp rated relay outputs for 3-speed fan |
Sensor | NTC 5K |
Temperature Control Range | 5-35°C (41°F-95°F) |
Accuracy | ±0.5°C@25°C |
Display | LCD |
Net Weight | F2000LB: 260g F2000PS/PSC series: 280g |
Dimensions | F2000LB-S: 120mm(L)×90mm(W)×22mm(H)+28.5mm(bulge) F2000PS: 130mm(L)×90mm(W)×32mm(H) |
Mounting Standard | Mounting on or inside the wall, 2“×4“/ 65mm×65mm box |
Standard | CE-Approval for F2000PS series |
¨ Models
Types | Model | Characteristic |
F2000LB Series FCU thermostat for 2-pipes FCU systems | F2000LB-S-21 | 3-speed fan auto adjustment, 1*on/off output to a 2-wire/3 wire water valve cooling/heating manual switch |
F2000LB-S-21-K | 3-speed fan auto adjustment, 1*on/off output to a 2-wire/3 wire water valve. Key-card option. cooling/heating manual switch | |
F2000PS Series FCU thermostat for 2-pipes or 4-pipes FCU systems | F2000PS-21 | 3-speed fan auto or manual adjustment with each 5A rated load, 1X on/off output to one 2-wire water valve. cooling/heating manual switch |
F2000PS-22 | 3-speed fan auto or manual adjustment with each 5A rated load, 2X on/off outputs to two 2-wire water valves for 4 pipes systems cooling/heating changeover. | |
F2000PS-22-K | 3-speed fan auto or manual adjustment with each 5A rated load, 2X on/off outputs to two 2-wire water valves for 4 pipes systems. cooling/heating changeover. Key-card option | |
FCU thermostat with Modbus RS485 interface | F2000PSC-21 | 3-speed fan auto or manual adjustment with each 5A rated load, 1X on/off output to one 2-wire water valve. Modbus RS485 communication interface. |
F2000PSC-22 | 3-speed fan auto or manual adjustment with each 5A rated load,, 2X on/off outputs to two 2-wire water valves for 4 pipes systems. Modbus RS485 communication interface | |
F2000PSC-21-K | 3-speed fan auto or manual adjustment with each 5A rated load, 1X on/off output to one 2-wire water valve. Key-card option. Modbus RS485 communication interface. | |
F2000PSC-22-K | 3-speed fan auto or manual adjustment with each 5A rated load,, 2X on/off outputs to two 2-wire water valves for 4 pipes systems. Key-card option. Modbus RS485 communication interface | |
Types | Options | Characteristic |
Options for above models | Blue Backlight -EL | Blue backlight of LCD. |
Remote Control-R | Infrared remote control | |
Sensor External-W | Temperature sensor is external (cannot be used with Key-card option) |