Factory Direct Sell Water Jet Vacuum Pump
USD $1 - $650 /Set
Min.Order:1 Set
Zhengzhou Keda Machinery And Instrument Equipment Co., Ltd.
Brief introduction
Circulating water multipurpose vacuum pump is the device with circulating water as working fluid, and it adopts jet technology to create negative pressure. According to the appearance is divided into desktop type and vertical type ( vertical type has larger capacity relatively). Desktop type also is divided into anti-corrosion type and stainless steel type, according to motor material. Transparent tank vacuum pump is available.
The pump adopts one modeling shell, small size on the basis of multi-purpose vacuum pump. It has small volume, light weight, beautiful appearance etc characters. Double-meter, double-tap pump and four-meter four-tap, double-side multi-purpose pumps is easy to do visual experiment for teachers as well as to turn off and on for students at any side.
Features
♦ Double taps, two vacuum meters, alone or in parallel.
♦ Newly improved anti-corrosion four taps, with four vacuum meters, alone or in parallel.
♦ Motor material: stainless steel or anti-corrosion material.
♦ Corrosion resistance pump, free-pollution, low noise and move easily. Vacuum regulator is available according to customer’s needs.
♦ Accommodate four people for chemical test, reduces the cost, and also saves the space.
♦ To prevent it to work long hours after high temperature, vacuum degree is reduced, specially add ice hole to add ice when water temperature too high vacuum degree reduced.
♦ Reasonable design, compact structure, security encapsulation.
♦ Absorb the harmful gas, environmental friendly, to ensure physical and mental health.
♦ Resistance to acid and alkali solvent
♦ Special customized motor by well-known manufacturers, fluorine rubber mechanical seal to keep no corrosive gas into the motor.
♦ Water circulation to save precious water resources.
Application
It provides vacuum condition for evaporation, distillation, crystallization, drying, distillation, filtration pressure, vacuum degassing experiments. Especially suitable for colleges and universities, research institutes, chemical, pharmaceutical, biochemical, food, pesticides, agricultural engineering, biological engineering etc industries’ scientific research, pilot and production .
Technical Parameter
Model | SHZ-D (Ⅲ) | SHZ-D(Ⅲ) four-meter, four tap | Remark |
Power (W) | 180 | 370 | Can equipped with 2L, 5L glass reactor or rotary evaporator. The vacuum is better when the water temperature is between 4℃ and 10℃. |
Voltage (V/Hz) | 220/50 | ||
Flow (L/min) | 60 | ||
Lift (m) | 8 | ||
Body material | Anti-corrosion /1Cr18 | Anti- corrosion | |
Max. pressure (Mpa) | 0.098 | ||
Sucking rate for single tap(L/min) | 10 | ||
Quantity of tap (Pcs) | 2 | 4 | |
Tank capacity (L) | 15 | ||
Dimension(mm) | 400*280*420 | ||
Weight(kg) | 15 | ||
Ultimate vacuum (kpa) | 26 | ||
Security performance | Anti~corrosion, counter~current prevent valve |
Notes: This machine is double tap or four taps, each vacuum gauge to display the corresponding vacuum degree of suction head.
Product details
Packaging
-Wooden case packaging;
-Both neutral and customized packaging can be available.
Shipping
-We can ship the goods to you by International Express such as DHL, TNT, EMS, FedEX and so on and you can also choose the appropriate one based on your timeline and budget. Besides, you can definitely choose to use your own shipping agent.
Service Promise
1. Products quality guarantee is for one year, after the product was sold.
2. In the warranty period, the users operate according to instruction but meet problems, our company will maintain free of charge.
3. Beyond the warranty period, products problems can also be solved by my company maintenance, but charge wiring components fees properly.
Technology Service
1. We have a mobile repair service team in our company, to carry out maintenance, consulting services in China for many years.
2. Users encounter problems when using our products, please contact us by telephone or email, we will be ready to provide consulting, maintenance and other services immediately.
zhengzhou keda Machinery and Instrument Equipment Co., Ltd, established in 1981, is a famous manufacturer of Lab equipment located in the central China. We specialized in rotary evaporator, jacketed glass reactor, single layer glass reactor, circulating water vacuum pump, low temperature reaction bath (slot), low temperature cooling fluid circulating pump(cool chiller), vacuum drying oven, blast drying oven, high-pressure reaction kettle, freeze dryer(lyophilizer), water/oil bath, magnetic heating stirrer, hydrothermal synthesis reactor, heating mantle, lift table and so on.
Though our foreign trade is not for long, we do have a history of more than 30 years for domestic trade. To assure the good quality & good service is our consistent aim.
Good quality and service are the keys to enterprise's success or failure, we would like to with the greatest efforts to create the best products and service.
Malfunction |
Failure causes |
Maintenance method |
Without the vacuum | 1. Vacuum nozzle is blocked by foreign body. 2. The filter in the lower part of the pump is blocked by foreign body. 3. Vacuum nozzle coil buckling loosened. | 1. Elimination the foreign body in nozzle hole. 2. Elimination the foreign objects on the filter, keep the water clean. 3. Tighten the threaded by hand. |
Vacuum meter hand do not move or swing | 1. The ventilation key way. behind the vacuum gauge is blocked. 2. Vacuum hands swing, maybe the backwater valve leaking or vacuum nozzle leaking. | 1. Remove the vacuum gauge, cleaning up the ventilation keyway. 2. Tighten connection plug of each hose, check backwater valve or valve pad, cleaning backwater valves, fastening vacuum nozzles |
Does not start or leakage | 1. After power on, motor buzzing does not start is blade stuck. 2. The motor does not turn suddenly is the lines of power or insurance have been cut off. 3. Chassis hemp hand, mostly is the line do not secure socket shell or socket did not install the ground wire. | 1. Cut off the power, rotate the fan blade in the motor cover helps to move again and then open it again. 2. Check the line, replace fuse, and dredge the circuit. 3. Exclude socket shell phenomenon, add ground wire socket.
|
Matters needing attention | Because the pump adopt mechanical seal, please add water before use it. It is forbidden to empty running it in case of mechanical seal parts is damaged. |