KD Table Model Circulating Water Vacuum Pump
KD Table Model Circulating Water Vacuum Pump
KD Table Model Circulating Water Vacuum Pump
KD Table Model Circulating Water Vacuum Pump
KD Table Model Circulating Water Vacuum Pump
KD Table Model Circulating Water Vacuum Pump

KD Table Model Circulating Water Vacuum Pump

USD $1 - $700 /Set

Min.Order:1 Set

Supply Ability:
600 Set / Sets per Month
Port:
Qingdao/Shanghai/Tianjin/Lianyungang/Ningbo/Guangzhou etc.
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Place of Origin:
Henan, China
Brand Name:
ZZKD
Model Number:
SHZ-95B
Theory:
Vacuum Pump
Structure:
Single-stage Pump
Usage:
Water

Zhengzhou Keda Machinery And Instrument Equipment Co., Ltd.

Business Type: Manufacturer,Trading Company
Zhengzhou Henan China
Main Products: Glass reactors ,Rotary evaporators ,Cool chillers ,Drying ovens ,High pressure reactors

Product Details

                          KD Table Model Circulating Water Vacuum Pump

 

Product Description

Function

This product is a new type vacuum suction pump design based on recycled water as the working fluid, the principle of negative pressure produced by jet. It is provide vacuum for chemical experiments and also can provide circulating cooling water to the reaction set.

The pumps are widely used in evaporation, distillation, crystallization, filtration, decompression, sublimation and so on. It is the ideal equipment in universities pharmaceutical, chemical, food processing and other areas in laboratory.

KD Table Model Circulating Water Vacuum Pump

Technical data

Model

SHZ-C

SHZ-C

SHZ-95B

Remark

Power (W)

370

Equipped with 10L, 20L, 50L glass reactor or rotary evaporator. The vacuum degree is better when the water temperature is between 4 and 10

 Voltage (V/Hz)

220/50

Flow (L/min)

80

 Body Material

1cr18

polypropylene

Anti-corrosive

Lift (m)

12

Max. Vacuum (Mpa)

0.098

 Sucking rate for single tap (L/min)

10

Quantity of tap (Pcs)

5

3

5

Tank capacity (L)

50

Dimension(mm)

450*340*870

450*340*840

Weight (kg)

37

Security performance

check-valve

Features

1. Water-saving effect is remarkable. The water in the water tank of the machine can be recycling, which is overcome the phenomenon of large amount of waste water when direct blow down tap water for vacuum. After testing, in one working day, continuous use may save water more than 8 tons, and the water can be use for a long time at a time. It is particularly suitable for tall building laboratory which is lack of water or insufficient water pressure.

2. Multi-function versatility application. This machine can provide vacuum conditions, besides, it also can provide circulating cooling water to the reaction device. This machine is connected to water, through appropriate supplement water, can continuous cycle operation for long time and keeping the inside temperature does not rise, the vacuum does not drop. Different models have different vacuum taps device, ranging from 2-5, the operator can work alone or in parallel operation.

3. Corrosion-resistant,no pollution.The machine shaft made of stainless steel material: the pump head, impeller, jet device and other key components.Using acid, alkali resistance A.B.C engineering plastics, copper, plastic Wang and other materials, plastic materials for the water tank.According to user needs can be freely chosen, is not from the effects of corrosive substances such as acid, alkali solvents and so on and also does not contaminate the laboratory.

4. Novel appearance, easy to operate. The pump head directly immersed in water, minus the complicated water diversion devices.Bottom with brake caster, easy to move, the upper part with detachable table cover, easy to add water, ice or overhaul.

5. The machine running low noise, stable performance. Also have the advantage of a small size, small footprint, light weight and so on.

KD Table Model Circulating Water Vacuum PumpKD Table Model Circulating Water Vacuum Pump

Instructions
1. Add enough circulating water. Put the machine on the worktable steadily, first use, please open the mouth which is add water, ice. Then, pour into cool tap water, observe the water level float, stop adding water when the water level reaches the best level scale.

2. Power on. Please correctly connected the power cord between the machine and power supply.

3. Vacuum operation. Please let the suction cannula tightly attached to the suction mouth, checking circulating water switch to make it closed, then read out the indicated vacuum degree.

4. Provide circulating cooling water. When you need to provide recycled water to the reaction device, please contact the circulating water device with cannula, and then start the water cycle switch, you can realize the supply of circulating cooling water.

5. Outside the natural cycle. When the machine needs long time operation , in order to prevent the circulating water temperature rising and affect the vacuum effect, we can use a hose connected to water, control the tap water flow properly and let it formed natural circulation state. We also must continuous supplement and replace the cool water to keep circulating water temperature does not rise, it will not affect the vacuum effect.

KD Table Model Circulating Water Vacuum PumpKD Table Model Circulating Water Vacuum Pump

KD Table Model Circulating Water Vacuum Pump

Packaging & Shipping

Packaging

-Plywood or carton packaging;
-Both neutral and customized packaging can be available.
Shipping
-We can ship the goods to you by International Express such as DHL, TNT, EMS, FedEX and so on and you can also choose the appropriate one based on your timeline and budget. Besides, you can definitely choose to use your own shipping agent.

Our Services

1. Pre-service
24 Hours online service for your consult.
Help choose right model,and a series of service,person,advise.
2. Middle service
--Give you best offer
--Provide discount for many sets order
--Do customer's request:
--Choose payment term you convienent.
--Promptly production and delivery,inform you in time.
--Can provide invoice value as you like to decrease your tax.
3. After sale service
--1 year warranty service and all life maintenance.
--Technical Egineer are avalible for oversea trainning.
--Free change for some parts
--Remote control technical consult
--Free installation DVD
--Maintenance plan
4. Good Packaging
All products are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.

Company Information

Zhengzhou Keda Machinery and Instrument Equipment Co., Ltd. is specialized in R & D, production, sales, teaching and chemical biology pharmacy equipment integrated company.Company tenet: keeping reputation, valuing contracts, supplying lower prices and better quality equipments to serve the cause of China's scientific research.
Our company always adheres to the "quality casting brand, professional achieves service" business philosophy, and the main product  is rotary evaporator, jacketed glass reactor, single layer glass reactor, circulating water vacuum pump, low temperature reaction bath (slot), low temperature cooling fluid circulating pump(cooling chiller), vacuum drying oven, blast drying oven, high-pressure reaction kettle, freeze dryer(lyophilizer), water/oil bath, magnetic heating stirrer, hydrothermal synthesis reactor, heating mantle, lift platform, etc. 

KD Table Model Circulating Water Vacuum Pump

FAQ

Malfunction

Failure causes

Maintenance method

 

 

 

Without the vacuum

1. Vacuum nozzle is blocked by foreign body.

2. The filter in the lower part of the pump is blocked by foreign body.

3. Vacuum nozzle coil buckling loosened.

1. Elimination the foreign body in nozzle hole.

2. Elimination the foreign objects on the filter, keep the water clean.

3. Tighten the threaded by hand.

 

 

 

Vacuum meter hand do not move or swing

1. The ventilation key way. behind the vacuum gauge is blocked.

2. Vacuum hands swing, maybe the backwater valve leaking or vacuum nozzle leaking.

1. Remove the vacuum gauge, cleaning up the ventilation keyway.

2. Tighten connection plug of each hose, check backwater valve or valve pad, cleaning backwater valves, fastening vacuum nozzles

 

 

 

 

Does not start or leakage

1. After power on, motor buzzing does not start is blade stuck.

2. The motor does not turn suddenly is the lines of power or insurance have been cut off.

3. Chassis hemp hand, mostly is the line do not secure socket shell or socket did not install the ground wire.

1. Cut off the power, rotate the fan blade in the motor cover helps to move again and then open it again.

2. Check the line, replace fuse, and dredge the circuit.

3. Exclude socket shell phenomenon, add ground wire socket.

 

 

 

Matters needing attention

Because the pump adopt mechanical seal, please add water before use it. It is forbidden to empty running it in case of mechanical seal parts is damaged.

 

 

Contact Supplier

Telephone
86-0371-87783156
Fax
86-0371-60920178
Address
Room 201 Block B #2 Building, the National 863 Software Park, CuiZhu Street #6 Zhengzhou,Henan

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Mechanical Parts & Fabrication Services > Pumps & Parts > Pumps
Categories
Hi~