blocks heater and cooling machine

blocks heater and cooling machine

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Port:
Guangzhou
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Brand Name:
A & E Lab
Model Number:
ABH-102(CL2)

A & E Lab Instruments (Guangzhou) Co., Ltd.

Business Type: Trading Company
Guangzhou Guangdong China
Main Products: Lab Instruments ,UV VIS Spectrophotometer ,Visible Spectrophotometer ,PCR-Cycler ,Hotplate Stirrers

Product Details

Specifications

blocks heater and cooling machine
1)Max.Block number:2;
2)With CE certificate;
3)Warranty:1 year.
4)with different block

A & E Lab Hot Selling are include: UV VIS Spectrophotometer, Visible Spectrophotometer, Flame Photometer, PCR-Cycler, Blocker Heater,Shaker Incubator,Melting Point Device, Hotplate, Stirrer, Stirrer Hotplate, Rotory Mixer, Tube Roller Mixer, 3D Rocker, See-Saw Rocker, Vortex Mixer, Orbital Shaker, Cold Keeper, etc.
Welcome to inquire us!

 

blocks heater and cooling machine

Block heater and cooler (ABH CL seriesare designed for widely use in Chemical, Biochemical, Clinical 

and other General Labs for storage, heating, digesting, incubating, concentrating and other heating 

and cooling processes, and due to the incorporating three stages temperature programming, it is much 

useful in enzymatic and other chemical catalytic reaction.

 

 

The (ABH CL seriesare using Peltier to fulfil the heating and cooling process.  It has the capacity to 

increase or decrease the block temperature to higher or lower than environmental temperature.  

In addition, the cooling capacity helps the machine quickly ramp down the temperature to the lower

temperature setting.  This is greatly helping the temperature reaching equilibrium quickly.

 

 

The machine accommodates many different variety of blocks regardless the different block thickness, 

25 mm, 35 mm, and 50 mm (for thicker blocks, it takes longer time to reach the equilibrium, or even 

very hard to reach the extreme temperature setting, such as 0 and 100 C).  It is designed to be relatively 

independent on the environmental temperature.  For example, if you set the temperature at 25 C, it 

becomes heating process when you operate the machine in the cold room (environmental temperature 

< 25 C), or cooling process when you operate the machine at environmental temperature > 25 C.  It is 

same case as whether the block temperature is higher or lower than the setting point, the machine can 

always start the correct process and to reach the correct setting point.

 

 

These machine differs from PCR and other heating/cooling machines in which the thermistor is located 

inside the sample blocks (or plates).  Even the dry block has similar configuration as the machine, the dry 

block can only use relatively identical block format (same block thickness) and use heating process only. 

Our unique control algorithm does not need any input from users, and can be operated in various cases: 

different block thickness, and different environmental status etc. It always can bring the block temperature 

to the closer points of the setting temperature point.

 

 

Since it can work more flexible than other heating/cooling machines, it sacrifices that the accuracy of the 

block temperature at setting points (it could be varied in the range of +/- 5 C).  We need a good calibration 

method to do quick correction to reach the accurate point.  The calibration must be easily to operate, and 

avoid the frequent calibration for the users.

 

 

In normal calibration method, the calibration step must be done before running the sample.  It takes a long 

time and could be time consuming process.  Most importantly, the normal calibration methods (regardless 

multi-points calibration or change the value thru a potantiostat) change the system thermo-table value.  

It will greatly affect the performance of the machine and need to do very often calibration.  

 

 

The new calibration in the machine is totally different from present method.  There is no special calibration

step in the machine.  The calibration can only be done in the equilibrium stage during run.  In the 

equilibrium stage, users enter the correct value, and the machine will start to run again to reach the new 

equilibrium point.  At this time, the timing will be paused if running the timer, and will be resumed after 

reaching the new equilibrium.  In the same time, the correct value will be stored in the memory as 

individual point.  The system thermo table remains unchanged.  In the next run, the machine will look 

up the memory to find the calibration value first, if it could not find, it will look back to the system table.  

The memory can store more than 70 points, and when the memories full, the new data will push out the 

oldest data out of memory.  

 

 

It has a warning light, and it will be turned on when the machine temperature reaching above 50 C.

 

 

There are three major thickness of blocks:

 

 

1.  The 50 mm thickness type of blocks, usually used for large volume and incubation or storage purpose.  

The maximum and the minimum block temperature can only reach 80 C and 10 C.

 

2.  The 35 mm thickness type of blocks, usually used for medium volume (5 – 10 ml vials).  It can reach the 

set temperature ranging from 0 - 100 C.  However, it could take longer time to reach the equilibrium point.

 

3.  The 25 mm thickness of type of blocks, usually used for smaller volume (up to 2 ml vials).  It is designed 

to use in enzymatic, catalytic and other chemical reaction which required fast ramping rate reaction.

 

Technical Specification:

 

Model

ABH-101 (CL1)

ABH-102 (CL2)

Temperature Range

0 (< room temp - 25C) to 100 C

0 (< room temp - 25C) to 100 C

Control

PID

PID

Max. Block Number

1

2

Temperature Stability

±0.1 C

±0.1 C

Temperature Maximum Variety 

between Identical Blocks @ 50 C

±0.2 C

±0.2 C

Ramping time ( min)

4 (from 0 - 100 C, without block); 

10 (from 100 - 0 C,  without block)

4 (from 0 - 100 C, without block); 

10 (from 100 - 0 C,  without block)

Timing (min)

999

999

Programming

3 stages temperature and timing

3 stages temperature and timing

Power Supply

100V – 230V, 120 W

100V – 230V, 240 W

Dimension LXWXH(mm)

210X260X150 (not include the sample 

chamber high 50 mm)

260X260X150 (not include the sample 

chamber high 50 mm)

Weight (KG)

3.9

4.9

 

 

Model

ABH-101 (CL1E)

ABH-102 (CL2E)

Temperature Range

0 (< room temp - 25C) to 100 C

0 (< room temp - 25C) to 100 C

Control

PID

PID

Max. Block Number

1

2

Temperature Stability

±0.1 C

±0.1 C

Temperature Maximum Variety 

between Identical Blocks @ 50 C

±0.2 C

±0.2 C

Ramping time ( min)

2 (from 0 - 100 C, without block); 

4 (from 100 - 0 C,  without block)

2 (from 0 - 100 C, without block); 

4 (from 100 - 0 C,  without block)

Timing (min)

999

999

Programming

3 stages temperature and timing

3 stages temperature and timing

Power Supply

100V – 230V, 240 W

100V – 230V, 480 W

Dimension LXWXH(mm)

260X260X170 (not include the sample 

chamber high 20 mm)

280X260X170 (not include the sample 

chamber high 20 mm)

Weight (KG)

5.4

6.9

 

 

blocks heater and cooling machineblocks heater and cooling machineblocks heater and cooling machineblocks heater and cooling machineblocks heater and cooling machineblocks heater and cooling machine

 

 

 

Contact Supplier

Ms. Ella Wu Managing Director Chat Now
Telephone
86-20-34216300
Mobile
15800016110
Fax
86-20-34216301
Address
#1708, 17F,New Century Plaza, No.2-6 Hongde Rd. Guangzhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Chemicals > Lab Supplies > Laboratory Heating Equipments
Categories
Hi~