Drawell-Emerald Auto Biochemistry Analyzer (800T/H),2016 new

Drawell-Emerald Auto Biochemistry Analyzer (800T/H),2016 new

USD $39,000 - $44,999 /Piece

Min.Order:1 Piece

Supply Ability:
500 Piece / Pieces per Month
Port:
Shanghai
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
DRAWELL
Model Number:
Drawell-Emerald
Place of Origin:
Shanghai, China

Shanghai Drawell Scientific Instrument Co., Ltd.

Business Type: Manufacturer,Trading Company
Shanghai China
Main Products: laboratory equipment ,Spectrophotometer ,Centrifuge ,Balance ,Incubator

Product Details

Drawell-Emerald Auto Biochemistry Analyzer (800T/H)

 

Parameter:

1. 800 test per hour,160 cuvettes

2. 180 sample position.

3. 200 refrigerated reagent position.

4. optical grating

 

Features:

1. Fully automated, Discrete, Random access,STAT priority,real-time dual wavelength.

2. Total open setting of items, supported different reagents from different countries.

3. Reversed optics and imported photo sensor make sure the precision of detection results.

4. Microsring injector imported from Germany assures the veracity of a trace of samples, 

sample step by 0.1 UL, reagent step by0.5 UL

5. 24 hour non-stop working, convenient emergency function with inserting emergency at random.

6. Implementing analysis of ultra-trace reaction solution to 100 UL, and saving more reagents.

7. Discrete cuvette, preventing from cross-infection, and be washed and reused, making sure accurate result and save cost.

8. Perfect self-detection function makes sure the analyzer in order and accurate result.

9. Software is easy to learn and use. And test report can be printed.

10. Perfect function of quality control management is convenient for users to manage the clinical test result.

11. Detecting in the whole reaction process with reaction curve, convenient for users to monitor thoroughly and scientifically analyze the detection data.

12. Supporting software can implement the function of detecting surplus reagent through liquid level induction of reagent probe.

 

 

Overall 

Performance 

Model 

Drawell-EMERALD 

Type 

Discrete, Fully automatic 

Throughput 

800T/H 

Analysis Method 

End-point, Fixed-time,Rate,etc 

Programming Items 

programmable for any test items 

Certification 

CE, FDA, ISO9001, ISO14001, ISO13485 

Sample unit 

Sample Position

180 samples, double disk design, including 60 samples for 

calibration/quality dribbling refrigerated

Sample Tubes

Original blood collection tube,micro tube,plastic tube,etc.

Sample Types 

Serum,plasma,urine,etc.

Sample Volume 

2ul ~70ul (0.1ul stepping) 

Sample Probe 

Having liquid level induction function, 

ensuring the accuracy of adding sample 

Probe Cleaning 

Automatic washing both interior and exterior ,

cross contamination rate < 0.1%

Analysis Items 

analyzing maximally 100 items at the same time 

Reagent unit 

Reagent Position 

200 reagent positions, dual-tray design

Wash Solution

Washing solution can be installed in any position, 

including needle, stir bar washing solution and 

water bath disinfectant

Reagent Volume 

20-350ul, 0.5ul increment

Temperature Control 

continuous2~8cooling within 24 hours 

Reagent Probe 

Having liquid level induction function, 

ensuring the accuracy of adding reagent. 

Inventory checking 

Probe cleaning 

Automatic washing both interior and exterior 

Reaction unit 

Reaction Volume

150-550ul

Reaction Temperature

37

Temperature system

Water bath,Real-time temperature display

Cuvettes 

160 positions with permanent hard glass cuvettes 

(optical path length 5mm) 

Stirrer 

Independent stir bar, nanotechnology, highly polished, 

automatic frequency conversion

Cleaning 

automatic water cleaning and drying system 

System Adjustment 

System can record the blank value and get more accurate 

result by deducting blank base value of each cuvette 

Optical System 

Light Source 

Halogen lamp, lamp can be auto sleep and wake up

Receiver 

Holographic flat field concave grating diode array detection

Wavelength Range 

16 wavelengths from 340 to 800nm

Linear Range 

-0.3000~3.3000 Abs

Stray light

< 0.1% or Abs > 3.0

Calibration and QC 

Calibration Method

Linear calibration:K factor,two- and multiple linear  Nonlinear

Calibration:spline,polynomial,Logarithm,etc. 

Quality Control 

Auto QC,cooled QC positions

Software 

Emergency Function 

Emergency sample can be placed in the sample tray at any time 

Software 

Windows XP (SP3) / Win 7 

Online

Full bi-directional communication possible

Data Processing 

Having reaction curve detection and data display function 

in the whole process 

Others 

Water consumption

Deionized water , <45 L/hour

Power Supply 

110-240V ,50Hz ,<1.5KW

Dimension 

1508×865.5×1204mm

Weight 

400Kg

 

Drawell-Emerald Auto Biochemistry Analyzer (800T/H),2016 newDrawell-Emerald Auto Biochemistry Analyzer (800T/H),2016 newDrawell-Emerald Auto Biochemistry Analyzer (800T/H),2016 newDrawell-Emerald Auto Biochemistry Analyzer (800T/H),2016 newDrawell-Emerald Auto Biochemistry Analyzer (800T/H),2016 newDrawell-Emerald Auto Biochemistry Analyzer (800T/H),2016 newDrawell-Emerald Auto Biochemistry Analyzer (800T/H),2016 newDrawell-Emerald Auto Biochemistry Analyzer (800T/H),2016 new

 

Contact Supplier

Mr. Cary Zeng Director of Export Chat Now
Telephone
86-21-50966080
Mobile
18721184858
Fax
86-21-50966080
Address
Room 211,Building 7,ShengYu Industrial Park,No.365 ChuanHong Road,PuDong,Shanghai,China Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Clinical Analytical Instruments
Categories
Hi~