DDC-8 resistivity meter,practical resistivity survey,resistivity equipment,earth resistivity meter,electrical resistivity meter,resistivity survey,resistivity meter,resistance meter,resistivity prospector,resistivity sounding,vertical electrical sounding,metal detector,earth resistance meter,geoelectric device,electrical resistance meter,geoelectrical method,soil resistivity meter
gold detector,fast find ore vein,copper prospector,portable mineral detector,lead ore prospector,zinc ore prospector,practical resistivity survey, resistivity equipment,earth resistivity meter,electrical resistivity meter,resistivity survey,resistivity meter, resistance meter,resistivity prospector,resistivity sounding,vertical electrical sounding,metal detector,earth resistance meter,geoelectric device,electrical resistance meter,geoelectrical method,soil resistivity meter,ground water detector,geological equipment,electrical prospecting,cavity detector, resistivity investigation,silver prospector,portable iron detector,geophysical prospecting instrument, groundwater detector/water locator/water detection device
1. With the variation of apparent resistivity, it is widely used for searching underground water and non-metal ores (quartz mine, calcite mine, coal ore and talc ore etc), which also plays an important role in sides as ores prospecting and water detect etc.
2. Micro-PC controlled, resistivity value read directly, multiple arrays, data protection when power-down.
3. It is applied for ground and sap’s electrical prospecting method like vertical electrical sounding (VES), electro-profile method, IP charge method and SP method etc. The applied field includes hydrology, environment, engineering prospecting, metal and non-metal mineral source detect etc.
Specifications:
Detect depth:200M
External HT supply: 10V~700V
Maximum supply current: 3000mA (without set for over-voltage and over-current protection)
Measuring voltage range: ±3000mV
Measuring accuracy: ±2%
Current measuring range: 0.1mA~3000mA; measuring accuracy: ±2%
Stored data: 800 points
Compensation range for natural potential: -1000mV~+1000mV
Input impedance: >30MΩ
Noise suppression against the industrial frequency of 50HZ: > 60dB
Operating temperature range: -10°C~+50°C