China wholesale cooling tower PVC sheet drift eliminators
USD $0.5 - $3.6 /Piece
Min.Order:1000 Pieces
Hebei Long Zhuo Trade Co., Ltd.
China wholesale cooling tower PVC sheet drift eliminators
Drift Eliminators, made out of rigid PVC, are designed to remove entrained particles from air steam efficiently,with minimum pressure drop, thereby reducing the fan power requirement when the air passes through the Drift Eliminator.Water droplets are separated from the air drift at the three direction change points on the drift eliminator.
For Cross flow tower applications, the almost vertical water conduits provided by the CD-100 drift eliminator remove the water droplets out of the drift eliminator area and return them back into the tower and does not allow any re-entry. The special locking pin arrangement for CD-100 facilitates quick and simple assembly at site.
For Counter flow applications,the CD-S130 drift eliminator provides a cellular rugged structure with a very low pressure drop.This results in high drift elimination efficiency while exerting minimum driving force on the fan. The CD-S130 drift eliminators get an S-shaped tubular structure as a result of their fabrication. Individual S-shaped corrugated sheets are bonded with subsequent layers to create the structure. The entire area is thus divided into several fine S shaped mini zones each removing water droplets on the entire surface of the cell.
1.Significantly block sunlight (70:1 light reduction) to reduce algae growth on interior surfaces of the cooling tower system, thus reducing the cost of algae-removal chemicals and labor.
2.Reduces noise leaving the tower through the louver modules by approximately three decibels.
3.Achieves very low pressure drop results.
4.Pre-assembled modules available in a variety of lengths.
5.Optional Assembly frames made of extruded PVC available for easy installation and access for cleaning and maintenance (mounting flanges available on 1, 2, or all 4 sides).
6.Rigid, UV-stabilized PVC meets Cooling Technology Institute Standard 136.
TECHNICAL DATA | |
Characteristics | DE |
Suggested Cooling Tower Application | Counter/Cross flow |
Type Of Structure | P |
Maximum Face Velocity (m/sec) | 4.0 |
Module Length | 600 - 3000 mm |
Module Width | 1200 mm or as required |
Module Depth | 100 mm |
Distance Between Profiles | 35 |
Directional changes for air flow | 3 |
Maximum Continuous Temperature (°C) | 65 |
1.Towers in Central Air Conditioning
2.Closed Circuit Cooling Towers in Heat Treatment Industry
3.Air Compressor Cooling System
4.Towers in Metallurgy Industry
5.Special Industry
More products:
Our Advantages:
a.We are the manufacturer, not only trading company, price will be much competitive
b.We have produced strictly in according to the customers’ request.
c. Our operational theme of “good Quality , high Credibility&best service".
Why Us: