hospital radiography system medical 200mA 20kw xray machines for sale
Negotiable /Set
Min.Order:1 Set
Guangzhou Yueshen Medical Equipment Co., Ltd.
YSX200G 200mA 20kw high frequency radiography medical x ray machine cost
3.5kw high frequency medical equipment hospital x ray machine mobile
easy operation 3.5kw high frequency mobile radiography x ray machine
Top quality 3.5kw high frequency medical hospital x-ray equipment mobile
YSX70GM-A hot sale high frequency mobile 3.5kw best price for x ray machine
sturdy durable and flexible 3.5kw high frequency radiography mobile xray unit
hospital radiography system medical 200mA 20kw xray machines for sale
model:YSX200G
Features of 20KW high frequency x-ray unit:
1.High precision control mode through analog & digital double-loop control: Adopting HF (≥30kHz)inverter circuit combined with analog & digital double-loop control mode (composed of microprocessor and PWM dedicated chip), in order to achieve high-precision high voltage output. Though power supply fluctuation may appear, steady x-rays can still be output.
2.High-precision control in radiography time: Minimum exposure time is 0.0025 second, and quick radiography is accessible at any time without the influence of power phase, thus high-quality x-ray films are easily achieved and x-ray radiation to patients is reduced.
3.High-precision tube current control: X-ray tube current using two high-frequency converter heating which is controlled by the microprocessor high-speed A / D converter sampling tube current calculate in real-time. The microprocessor control the allow load of the X-ray tube. It can be set out photographic conditions of expressing an effective X-ray tube capacity;
4.Various setting ways of Radiography conditions: you can select kV, mA and mAs to set the conditions for radiation, the programme way of the body parts is efficient, simplify operator's operation., limit the select of three parameters for protecting the capacity according to the capacity of x-ray tube.
5.Self-protection, self-diagnosis: Once the malfunction happen, generator protection device, alarm, chain can be inquires the fault code, convenient maintenance treatment
6.Compact structure, Reduces installation space.
Technical index of main component for High Frequency X-ray Machine:
Function: Radiography,single-table single tube.
1.Maximum output power
Intermittent mode: 100kV ,200mA,20kW.
2.Adjustment range of tube current,tube voltage.
tube current: Radiography 16mA~200mA
tube voltage: Radiography 40kV~125 kV.
3.Exposure Time:photography0.0025s~6.4s step adjustable
4.Frequency operation≥30kHz
5.The condition of power:
Power Voltage:380V±10%.
Power supply capacity: 120% the power of the equipment
Internal resistance:≤0.5Ω.
6.High frequency and high voltage x-ray generator(including microcomputer control console)
Frequency operation of high voltage x-ray generator≥30kHz.
Internal resistance: less than 0.5Ω.
Output power:20kW.
Output Voltage: Radiography: 40 kV~125kV, step 1kV,
Output Current: Radiography: 16mA~200mA,
Exposure Time: 0.0025s~6.4s.
Display:digital pipe display photography voltage Photography current photography time mAS of photography
X-ray tube
Max tube voltage:125kV Max tube current:400mA.
Small focus:1.0mm ,Big focus:2.0mm.
Speed of anode rotating:2800r/min.
Anode heat capacity:140KHU
7.Collimator
Collimator with fixed position lamp.
Power supply: Working voltage: 24V.
8.Radiography Bed:
Integration of the bed with stand column without skyrail design.
Length*width*height of bed surface:2000mm×760mm×690mm. Deviation:±10mm
Distance from table surface to film:50mm
Horizontal movement distance of table≥220mm
Vertical movement distance of table≥900mm Way of locking: Manually single automatic multi-optional
9.X-ray source component pillar:
With the scaleplate indicating the height of X-ray tube source component pillar.
Distance of vertical movement:770mm±10mm,+90°~-90°, deviation,±2°
Moving crosswise (left & right):+180°~-180°, deviation.±2°
Moving lengthways (along ground railway) ≥1300mm
10.Ray-filter of table: Fixed beam filtration grid density≥40 lines/cm.
Ray-filter grid:grid ratio 10:1,.Focus Distance:110cm.
11. Horizontal movement of Radiography device ≥500.
Braking force of electromagnetic≥98N, Button operation.
12.Limited beam splitter start and closedown should portable, flexible, reliable,can adjust to any Radiation field rectangle size.
13.Fixed beam filtration grid density≥40 lines/cm.
Ray-filter grid:grid ratio 10:1, Focus Distance:110cm.
Cassette size:5″×7″ 8″×10″ 10″×12″ 11″×14″ 14″×17″.
High Frequency X-ray Machine.
Product Configuration:
X-ray tube,1 set
Radiography Table,1 set
Collimator,1 set
High-voltage generator, 1 set
Micro console, 1 set
High-voltage cable, 2 pieces
Vertical bucky stand 1 set
High Frequency X-ray Machine
High performance High Frequency X-ray Machine
20kw medical radiography High Frequency X-ray Machine
High frequency High Frequency X-ray Machine
High Frequency X-ray Machine prices
hospital radiography system medical 200mA 20kw xray machines for sale
For more medical equipment, please go to our Alibaba homepage and search by catagories. Thanks for your interest!
Contact Person:Iris Chen
Mob:+0086 13826442089 (whats app also available)
Skype: ysenmediris
E-mail also welcome!
200mA 20kw high frequency radiography medical x ray machine cost