model:YSX200G
Features of 20KW high frequency x-ray unit:
1.High precision control mode through analog & digital double-loop control: Adopting HF (≥30kHz)inverter circuit combined with analog & digital double-loop control mode (composed of microprocessor and PWM dedicated chip), in order to achieve high-precision high voltage output. Though power supply fluctuation may appear, steady x-rays can still be output.
2.High-precision control in radiography time: Minimum exposure time is 0.0025 second, and quick radiography is accessible at any time without the influence of power phase, thus high-quality x-ray films are easily achieved and x-ray radiation to patients is reduced.
3.High-precision tube current control: X-ray tube current using two high-frequency converter heating which is controlled by the microprocessor high-speed A / D converter sampling tube current calculate in real-time. The microprocessor control the allow load of the X-ray tube. It can be set out photographic conditions of expressing an effective X-ray tube capacity;
4.Various setting ways of Radiography conditions: you can select kV, mA and mAs to set the conditions for radiation, the programme way of the body parts is efficient, simplify operator's operation., limit the select of three parameters for protecting the capacity according to the capacity of x-ray tube.
5.Self-protection, self-diagnosis: Once the malfunction happen, generator protection device, alarm, chain can be inquires the fault code, convenient maintenance treatment
6.Compact structure, Reduces installation space.
Technical index of main component for High Frequency X-ray Machine:
Function: Radiography,single-table single tube.
1.Maximum output power
²Intermittent mode: 100kV ,200mA,20kW.
2.Adjustment range of tube current,tube voltage.
²tube current: Radiography 16mA~200mA
²tube voltage: Radiography 40kV~125 kV.
3.Exposure Time:photography0.0025s~6.4s step adjustable
4.Frequency operation≥30kHz
5.The condition of power:
²Power Voltage:380V±10%.
Power supply capacity: 120% the power of the equipment
²Internal resistance:≤0.5Ω.
6.High frequency and high voltage x-ray generator(including microcomputer control console)
²Frequency operation of high voltage x-ray generator≥30kHz.
²Internal resistance: less than 0.5Ω.
²Output power:20kW.
²Output Voltage: Radiography: 40 kV~125kV, step 1kV,
²Output Current: Radiography: 16mA~200mA,
²Exposure Time: 0.0025s~6.4s.
²Display:digital pipe display photography voltage Photography current photography time mAS of photography
²X-ray tube
²Max tube voltage:125kV Max tube current:400mA.
²Small focus:1.0mm ,Big focus:2.0mm.
²Speed of anode rotating:2800r/min.
²Anode heat capacity:140KHU
7.Collimator
²Collimator with fixed position lamp.
²Power supply: Working voltage: 24V.
8.Radiography Bed:
²Integration of the bed with stand column without skyrail design.
²Length*width*height of bed surface:2000mm×760mm×690mm. Deviation:±10mm
²Distance from table surface to film:50mm
²Horizontal movement distance of table≥220mm
²Vertical movement distance of table≥900mm Way of locking: Manually single automatic multi-optional
9.X-ray source component pillar:
²With the scaleplate indicating the height of X-ray tube source component pillar.
²Distance of vertical movement:770mm±10mm,+90°~-90°, deviation,±2°
²Moving crosswise (left & right):+180°~-180°, deviation.±2°
²Moving lengthways (along ground railway) ≥1300mm
10.Ray-filter of table: Fixed beam filtration grid density≥40 lines/cm.
Ray-filter grid:grid ratio 10:1,.Focus Distance:110cm.
11. Horizontal movement of Radiography device ≥500.
Braking force of electromagnetic≥98N, Button operation.
12.Limited beam splitter start and closedown should portable, flexible, reliable,can adjust to any Radiation field rectangle size.
13.Fixed beam filtration grid density≥40 lines/cm.
Ray-filter grid:grid ratio 10:1, Focus Distance:110cm.
Cassette size:5″×7″ 8″×10″ 10″×12″ 11″×14″ 14″×17″.
High Frequency X-ray Machine.
Product Configuration:
X-ray tube,1 set
Radiography Table,1 set
Collimator,1 set
High-voltage generator, 1 set
Micro console, 1 set
High-voltage cable, 2 pieces
Vertical bucky stand (Optional), 1 set
High Frequency X-ray Machine
High performance High Frequency X-ray Machine
20kw medical radiography High Frequency X-ray Machine
High frequency High Frequency X-ray Machine
High Frequency X-ray Machine prices
High Frequency X-ray Machine
For more medical equipment, please go to our Alibaba homepage and search by catagories. Thanks for your interest!
Contact Person:Iris Chen
Mob:+0086 13826442089 (whats app also available)
Skype: ysenmediris
E-mail also welcome!
High Frequency X-ray Machine