20kw high frequency medical Radiography xray machine
Negotiable /Set
Min.Order:1 Set
Guangzhou Yueshen Medical Equipment Co., Ltd.
20kw high frequency medical Radiography xray machine
Features
1. High precision control mode: Adopting HF (≥30kHz) inverter circuit combined with
analog & digital double loop control mode (composed of microprocessor and PWM dedicated chip).
2. High-precision control in radiography time: Minimum exposure time is 0.0025 second, and quick radiography is accessible at any time without the influence of power phase, thus high-quality images are easily achieved and radiation to patients is minimized.
3. High-precision tube current control: The heating of x-ray tube adopts dual-stage high frequency converter, through taking sample tube current by high-speed running A/D converter and implement real-time control through micro-processor.
4. Various parameter-setting keys: You can select kV, mA and mAs to set the desirable radiography conditions.With quick human body parts programming, it simplifies the operation
procedures.
5. Self-protection & self-diagnosis: Once malfunction occurs, generator will self-protection and give an alarm.
6. Compact structure, reduce installation space.
7. Digital upgradable.
Configuration
No | Part Name | Qty |
1 | X-ray tube | 1 |
2 | Radiographic floating table | 1 |
3 | Collimator | 1 |
4 | Microcomputer console | 1 |
5 | High-voltage generator, | 1 |
6 | High-voltage cable | 2 |
7 | Vertical bucky stand | 1 |
Technical specifications
CONTENTS | YSX200G(20kW) | YSX500G (50kW) |
Intermittent mode | 100kV, 200mA, 20kW | 100kV, 500mA, 50kW |
Power voltage | 380V±10% 50Hz±10% | 380V±10% 50Hz±10% |
Tube current | Radiography 16mA~200mA | Radiography 46mA~630mA |
Output voltage | Radiography 40-125KV step by 1kV; | Radiography 40-125KV step by 1kV; |
Resistance power | less than 0.5Ω | less than 0.5Ω |
Output power | 20kW | 50kw |
Exposure time | Radiography 0.0025s~6.4s adjustable | Radiography 3ms~6s adjustable |
Nominal frequency | 30kHz | 30kHz |
Anode rotating speed | 2800r/min | 2800r/min |
Anode heat capacity | 140KHU | 150KHU |
Focus | Small focus:1.0mm Big focus:2.0mm | Small focus: 0.6mm Big focus:1.0-1.2mm |
Length*width*height of bed surface | 2000mm×750mm×690mm Deviation:±10mm | 2000mm×750mm×690mm Deviation:±10mm |
Horizontal movement distance (table) | ≥200mm | ≥200mm |
Vertical movement distance (table) | ≥900mm | ≥900mm |
Distance from table surface to film | 50mm±2mm | 50mm±2mm |
Distance of vertical movement | 770mm±10mm; | 800mm-1100mm |
Moving crosswise (left & right) | +180°~-180° deviation<±2° | +180°~-180° deviation<±2° |
Moving lengthways (along ground railway) | ≥1300mm | 600mm |
Fixed beam filtration grid density | ≥40 lines/cm. | ≥40 lines/cm. |
Grid ratio | 10:01 | 10: 01 |
Focus Distance | 100cm | 100cm |
Cassette sizes | 5″×7″ 8″×10″ 10″×12″ 11″×14″ 14″×17″ | 5″×7″ 8″×10″ 10″×12″ 11″×14″ 14″×17″ |