The unique UPT POCT test reagent in China
The unique UPT POCT test reagent in China
The unique UPT POCT test reagent in China

The unique UPT POCT test reagent in China

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Port:
Beijing Tianjing Shanghai

Quick Details View All >

Type:
Biochemical Analysis System
Brand Name:
HY
Model Number:
UPT
Place of Origin:
Beijing, China

Beijing Health Care Resource International Co., Ltd.

Business Type: Trading Company
Beijing China
Main Products: Medical equipment ,hospital product ,veterinary product ,lab equipment

Product Details

The unique UPT POCT test reagent in ChinaThe unique UPT POCT test reagent in China

 

Up-converting phosphor quantitative immunoassay analyzer

 

The unique UPT POCT test reagent in China

 

Principle

 

UPT is through infrared light inspires

luminescence particles, which radiates visible

light and realizes the energy up-converting

from low to high; this light is from crystal

structure avoiding quenching. Furthermore,

there is no this kind of light in nature, no any

interference, accuracy and stability.

 

Up-converting Phosphor Technology

 

The Lancet concludes that Lp-PLA2 is an indepandent prognosis factor of cardiovascular disease

 

 

The highest sensitivity,the lowest detection limitation; The only POCT reagent that

 

can meet PCT minimum requirements in Respiratory department of China

 

The POCT is equipped suitably for technology products which is uniquely recommend

 

by CHINA ASSOCIATION OF MEDICAL EQUIPMENT

 

 

The unique POCT test reagent in China

 

 

Anti-CCP is the unique luminescent quantitative POCT test reagent in China

 

Feature

Rapid

Reading takes less than 40 seconds, can realize up to 100 tests per hour;

Total testing time for single test including sample addition, incubation and

reading takes averagely 15-20 minutes, facilitating on-site and emergency diagnostics;

Flexible

 

Reliable

UP-converting phosphor appears in crystal structure, avoid luminescence quenching;

Adopt RFID chip recording standard curve of detection;

Without any damage to environment, detector, detected, detection

High stability and long shelf life

High precision

 

CE certified 

 

Lp-PLA2

Clinical Significance

The independent risk marker for cardiovascular disease

The specificity forecast biomarker of cardio vascular events

Reference Range: normal<175ng/ml

The Lancet concludes that Lp-PLA2 is an indepandent prognosis factor of cardiovascular disease

Liner Range: 5ng/ml-800ng/ml

UPT:Sensitivity: 5ng/ml

Test Time: Outboard reaction 15 minutes, onboard test 30s

Storage: 4-30℃

High-level Lp-PLA2 indicates that artheromatous plaque

is much easier to break

Reflect atheromatous plaque severity, distinguish effectively

benign and malignant plaque

Predict independently atherosclerosis causes

cardiovascular disease

Atherosclerosis causes cardiovascular disease

prognosis evaluation

Assessment of statins treatment

 

NT-proBNP

------The conventional indicator of Heart Failure diagnosis

and treatment monitoring

 

The best biomarker of diagnosis and exclusion heart failure

Diagnosis and risk stratification of heart failure

Specimen: Serum/plasma/whole blood

Reference Range: normal <125pg/ml

Linear Range: 5pg/ml-35000pg/ml

UPT: Sensitivity: 5pg/ml

CG:Sensitivity: 200pg/ml

Test Time: 15 minutes

Storage: 4-30℃

Distinguishing dyspnea caused by heart failure from

other diseases

Monitoring and prognostic assessment of heart

failure treatment

Screening and diagnosis of non-cardiac heart

failure patients

Assisting risk stratification of ACS

 

cTnI

------Diagnosis of acute myocardial infarction, unstable

angina pectoris and assist to diagnose Heart Failure

 

As an aid in the early diagnosis of Acute

Myocardial Infarction (AMI)

Acute Myocarditis, Unstable Angina, Acute

Coronary Syndrome (ACS).

Evaluating the severity of myocardial damage

As an aid in the prognosis of ACS

 

Specimen: Serum

Reference Range: normal<0.5ng/ml

Linear Range: 0.1ng/ml~40ng/ml

UPT: Sensitivity: ≤ 0.1ng/ml

CG: Sensitivity: 0.5ng/ml

Test Time: Outboard reaction 15 minutes, onboard test 30s

Storage: 4-30

 

CK-MB/MYO

—— The early stage biomarker of clinical diagnosis and

prognosis evaluation of myocardial injury.

 

Early diagnosis and risk stratification of ACS

Early diagnosis and treatment of MI

Distinguishing different causes of chest pain

Evaluating the size of myocardial ischemic area

Evaluating the function of left ventricle

 

Specimen: Serum/plasma

Reference Range: normal<49.9ng/ml

Linear Range: 1ng/ml~80ng/ml

UPT:Sensitivity: 1ng/ml

Test Time: Outboard reaction 15 minutes, onboard test 30s

Storage: 4-30

 

H-FABP

------The early stage marker of myocardial damage and high specificity of heart damage

 

Colloidal Gold Technology

Up-converting Phosphor

Technology

 

Early diagnosis of AMI

ACS prognosis evaluation

Re-infarction diagnosis

Specimen: Serum/plasma

Reference Range: normal<7ng/ml

Linear Range: 1ng/ml-100ng/ml

UPT:Sensitivity: ≤1ng/ml

CG: Sensitivity: <7ng/ml

Test Time: Outboard reaction 15min at room temperature, onboard test 30s

Storage: 4-30

 

D-dimer

------Early stage exclusion and diagnosis indicator of the deep vein thrombus and pulmonary embolism

 

The best biomarker of diagnosis and exclusion

heart failure

Diagnosis and risk stratification of heart failure

Distinguishing dyspnea caused by heart failure

from other diseases

Monitoring and prognostic assessment of heart

failure treatment

Screening and diagnosis of non-cardiac heart

failure patients

Assisting risk stratification of ACS

Specimen: Serum/plasma/whole blood

Reference Range: normal <500pg/ml

Linear Range: 50pg/ml-2000pg/ml

UPT: Sensitivity: 5pg/ml

CG: Sensitivity: 200pg/ml

Test Time: 15 minutes

Storage: 4-30

 

PCT

  -----The high specific indicator of bacterial infection diagnosis

 

Differentiation and diagnosis of bacteria & virus infection

Bacterial infection severity and prognosis evaluation

Treatment monitoring

Guide reasonable application of the antibiotics

 

Specimen: serum/plasma

The highest sensitivity,the lowest detection limitation; The only POCT reagent that

can meet PCT minimum requirements in Respiratory department of China

The POCT is equipped suitably for technology products which is uniquely recommend

by CHINA ASSOCIATION OF MEDICAL EQUIPMENT

Linear Range: 0.01~50ng/ml

UPT: Sensitivity: 0.01ng/ml

CG: Sensitivity: 0.5ng/ml

Test Time: Outboard reaction 20 minutes at room temperature; onboard test 30s

Storage: 4-30

 

IL-6

—— The warning marker of early inflammation and

sepsis occurrence

 

Up-converting

Phosphor

Technology

 

The unique POCT test reagent in China

Specimen: serum/plasma/whole blood

Reference Range: normal<7pg/ml

Linear Range: 3pg/ml-4000pg/ml

UPT:Sensitivity: 3pg/ml

Test Time: outboard reaction 15 min at room temperature, onboard test 30s

Storage: 3-40

 

Clinical Significance

The early stage biomarker of acute inflammation

The diagnosis of hematosepsis

The early stage warning of sepsis and diagnosis indicator

Infection severity and prognosis evaluation

 

CRP

------ Highly accurate test for the detection of inflammation and infection.

Risk assessment for cardiovascular inflammatory diseases

Specimen: serum/plasma

Reference Range: Infection normal<8mg/L; Cardiovascular normal<1mg/L

Linear Range: 0.5mg/ml-150mg/ml

UPT:Sensitivity: ≤ 0.5mg/ml

Test Time: Outboard reaction 3min at room temperature; onboard test 30s;

Storage: 3-40

An effective indicator for cardiovascular diseases

An indicator of common infection & assist to

distinguish bacterial/virus infection

 

Anti-CCP

------The high sensitivity and specificity indicator of Rheumatoid Arthritis diagnosis

 

The distinguishing and diagnosis of RA

RA early phase diagnosis indicator

RA treatment assessment and prognosis evaluation

Anti-CCP is the unique luminescent quantitative POCT test reagent in China

Specimen: Serum/plasma/whole blood

Reference Range: normal<25RU/ml

Linear Range: 25RU-1600RU/ml

CG:Sensitivity: 25RU/ml

Test Time: 15 minutes

Storage: 4-30

 

8 national invention patents

9 practical new types patents

 

Contact Supplier

Ms. yanping wang Sales Manager Chat Now
Telephone
86-10-67029165
Mobile
13701109331
Fax
86-10-67029135
Address
No1.Dacaochang hutong,Dongcheng District.Beijing Beijing

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Clinical Analytical Instruments
Categories
Hi~