fan coil unit
Negotiable /Set
Min.Order:1 Set
Jinan Shuangyi Environment Engineering Co., Ltd.
Fan coil unit
The FP series fan coil unit is our company independently develops and production, and pass the concerned national Department examination. The FP ventilator coiled pipe work as the central air conditioning's end equipment, can widely uses in the hotel, hospital, apartment, broadcasting station and other centralisms building which heating supplies. the FP series ventilator coiled pipe has the horizontal-type with hide installation, the vertical with hide installation,, horizontal type with no hide installation, vertical with no hide installation, acetabula on ceiling the type, the column type, the casette four outlet winds, the high static pressure types, the wall hanging type, the pipeline type and so on many kinds of forms.
It selects single-phase three fast fixed electric capacity electrical machinery, the insulation grade E level, uses the high quality bearing, the normal service life is not lower than for 12 years.
The automatic elbow and go up the coiled pipe welding had guaranteed the strip seam ripple coiled pipe had the higher gas side efficiency and the fluid side resistance. Two-sided spurts models, 8mm thick PE thermal insulation material and coiled pipe overall cementation, has avoided flaws and leakage
The main parameter
| FP-2.5 | FP-3.5 | FP-5.0 | FP-6.3 | FP-7.1 | FP-8.0 | FP-10 | FP-12.5 | FP-14 | FP-16 | FP-20 | |
The amount of wind m3/h | High | 250 | 350 | 500 | 630 | 710 | 800 | 1000 | 1250 | 1400 | 1600 | 2000 |
Middle | 180 | 290 | 420 | 510 | 600 | 650 | 880 | 1000 | 1100 | 1310 | 1700 | |
Low | 140 | 220 | 310 | 420 | 520 | 530 | 720 | 780 | 840 | 1090 | 1470 | |
The cooling amount w | High | 1480 | 2100 | 2900 | 3600 | 4200 | 4600 | 5600 | 6700 | 7800 | 8600 | 11200 |
Middle | 1070 | 1800 | 2400 | 3100 | 3500 | 3800 | 5200 | 6300 | 6400 | 7500 | 9900 | |
Low | 830 | 1300 | 1800 | 2500 | 2800 | 3000 | 4050 | 5600 | 5800 | 6370 | 7800 | |
The heating amount w | High | 2520 | 3100 | 4500 | 5300 | 6100 | 6900 | 7950 | 9900 | 11660 | 12750 | 15900 |
Middle | 1820 | 2400 | 4000 | 4380 | 4980 | 5200 | 6850 | 8700 | 9900 | 11250 | 13800 | |
Low | 1420 | 2000 | 3200 | 3500 | 4100 | 4600 | 6100 | 7500 | 8950 | 9300 | 12300 | |
Noise dBA |
| 32 | 35 | 36 | 36 | 38 | 41 | 42 | 44 | 47 | 50 | |
Input powerw |
| 30 | 33 | 40 | 50 | 65 | 80 | 96 | 120 | 140 | 160 | |
Volume of diversion (/h) |
| 350 | 500 | 650 | 720 | 830 | 1000 | 1250 | 1320 | 1550 | 1950 |