ENiCrMo-4 welding electrode 4.0mm
USD $100 - $100 /Kilogram
Min.Order:5 Kilograms
Zhengzhou Huitong Pipe Fittings Co., Ltd.
INCO-WELD C-276 welding electrode is used for shielded-metal-arc welding of INCONEL alloy C-276 and other nickel-chromium-molybdenum alloys. It is also used for surfacing of steel. The weld metal has excellent corrosion resistance in many media and is especially resistant to pitting and crevice corrosion. INCO-WELD C-276 welding electrode is useful for various dissimilar joints involving nickel alloys, stainless steels, and low-alloy steels.
The electrodes provide excellent operability for groove and fillet welding in the downhand position and the smaller diameter electrodes are also suitable for all position welding. Power supply: direct current, electrode positive.
Specifications
AWS A5.11 ENiCrMo-4(UNS W80276)
ASME II, Part C, SFA-5.11, ENiCrMo-4(UNS W80276)
ASME IX, F-No.43
DIN1736 EL-NiMo15Cr15W(2.4887)
(EN)ISO14172-SNi6276(NiCr15Mo15Fe6W)
Supply to these specifications available upon request
For manufacture to ASME III(NCA3800, NB2400), MIL, Rolls Royce, AMS and other specifications please refer your inquiry to the technical department prior to order placement.
Approvals
Canadian Welding Bureau
Other approvals may be applicable, please confirm details of current scope of approvals with the technical department prior to order placement.
Limiting Chemical Composition
Ni+Co | C | Mn | Fe | S | Cu | Si | Co | Cr | P | Mo | V | W | Others |
Remainder | 0.02 max | 1.0 max | 4.0-7.0 | 0.03 max | 0.50max | 0.2max | 2.50max | 14.5-16.5 | 0.04 max. | 15.0-17.0 | 0.35max | 3.0-4.5 | 0.50 max |
Minimum mechanical properties
Tensile strength, psi 100,000
Mpa 690
Elogation, 4d% 25
Filler metails available on spool and in cut straight lengths in a variety of sizes selected from the following diameters:
Available Product Forms-Supplied in 10lbs(4.54kg) hermeticalloy sealed containers
Dimeter | mm in | 2.4 3/32 | 3.2 1/8 | 4.0 5/32 | 4.8 3/16 |
Length | mm in | 229 12 | 356 14 | 356 14 | 356 14 |
Current(DC+) | A | 40-65 | 60-90 | 90-125 | 125-150 |