HAC Ammonia Cooling Evaporative Condenser
Product Description

 

HAC Ammonia Cooling Evaporative Condenser

Brief Introduction of the Ammonia evaporative condenser manufacturer

1.VS.Cooling Tower +Heat Exanger Combination
Closer approach to wet bulb temperature and reduce fouling improve process efficiency
2.VS.Air-Cooled Systems
10-20°C lower process temperatures ,less required space ,and lower energy consumption .
3.VS.Once –Through Systems
Reduces environmental impact ,saving up to 95% of the cooling water .
4.Reduced installed Cost And Space Requirements
Effectively combines the function of a cooling tower and heat exchanger into one piece of equipment ,reduce required piping and system complexity .

HAC Ammonia Cooling Evaporative Condenser

Technical parameters of the   Ammonia evaporative condenser manufacturer

Cooling Tower Total circulating water 

1800m3/h

Cooling Tower Inlet water temperature

43°C/33°C

Cooling Tower Out water temperature

35°C/25°C                            

Wet-bulb temperature

22°C/16°C                            

System Design pressure 

0.2MPa

Drift circulating water loss

0.01%                                

Cooling tower air intake

sides(inlet side of the barrier-free)

 

 

HAC Ammonia Cooling Evaporative CondenserStructure and main parts


1.Propeller Fan
2.Spray pump
3.Imported board of Zinc-plate and Aluminum-plate
4.Condensing Coils
5.Electronic Water-Curing Device
6.Set Up Dehydrator
7.Advantage Water Distribution System
8.PVC Wet Deck

 

Engineering considerations


1.Location
Closed Circuit Cooling Towers must have an adequate supply of fresh air to all inlets.
When units are located adjacent to building walls or in enclosure .Care must be taken to ensure that the warm ,saturated discharge air is not deflected and drawn back to the air inlets .
2.Think on compatibility of liquid (gas)
The fluid to be cooled must be compatible with the coil material .Fluids not compatible with ciol materials can lead to corrosion and tube failure .Certain fluids may require occasional pressure cleaning or mechanical cleaning of the inside of coil tubes .in such cases the coil must be designed to provide this capability .
3.Piping and Valves
Piping must be size and installed in accordance with good piping practice .All piping should be supported by pipe hangers or other supports ,not by the cooling tower .External shut off valves may also be required if the system design necessitates the isolation of individual tower cells .
4.Capacity Control
In general season ,the performance of most closed circuit cooling tower will vary dues to the change of its environmental wet bulb temperature .Therefore ,when the change of environmental temperature leads to the difference of liquid temperature ,in this case ,capacity control will be required . 

HAC Ammonia Cooling Evaporative Condenser

Application Fields


1.Towers in Central Air Conditioning
2.Closed Circuit Cooling Towers in Heat Treatment Industry
3.Air Compressor Cooling System
4.Towers in Metallurgy Industry
5.Special Industry

 HAC Ammonia Cooling Evaporative Condenser
HAC Ammonia Cooling Evaporative Condenser

 

 
FAQ 

FAQ

(1)Your company is a manufacture or trading company?

We are a leading cooling tower manufacturer for 38 years . It is“famous brand”-Heng An manufacture in China .

(2) What is the difference between a "counter flow" and a "cross flow" cooling tower?

The crossflow or counterflow designation characterizes the orientation of the airflow within the heat-transfer media (fill) in the tower with respect to the direction of water flow.

In counterflow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill media. Hence the air and water travel in opposite directions.

In crossflow cooling towers the air passes through the fill media in a horizontal direction, thus crossing the downward water flow. Counterflow towers are inherently more efficient than crossflow towers.

(3) What is your Minimum Order Quantity(MOQ)?

Our business model is both wholesale and retail, so our MOQ is one piece

(4) How do I get repair parts and how long does it take?

Complete Parts Workshop, and can supply all parts,

90% of Spare parts can be distributed to any place on the world within one week!

 

Welcome to China,Welcome to our factory !

HAC Ammonia Cooling Evaporative Condenser

Contact Supplier

Ms. yan li Manager Chat Now
Telephone
0086-0536-6103201
Mobile
13853661886
Fax
0086-0536-6103202
Address
Room 1210 no.2613 yuehe road ,kuiwen weifang city,shandong Weifang,Shandong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Machinery > Refrigeration & Heat Exchange Equipment > Cooling Tower
Categories
Hi~