Syringe pump 500II
USD $450 - $450 /Unit
Min.Order:5 Units
Guangzhou Global Healthcare Supplies Co., Ltd
Function and Features of Syringe Pump
1). 3 kinds of modes: Rate Mode, Time Mode, Body Weight Mode.
2). Double CPU: Making injection process safer and more reliable.
3). Accurate & sensitive pressure sensor: Detecting occlusion pressure accurately.
4). Injection time, dose, solution: Easy to be checked during injection process.
5). Precision step motor: No pulsating wave even during low-rate injection.
6). KVO & Bolus functions: Rate selectable according to actual clinical requirement.
7). Excellent injection operation: Accuracy ensured even at small-volume injection.
8). Unique injection supervision system: Ensures safe injection and reduces the nurse's workload.
9). Open system for syringes: Accept all brands of syringes of national standard from 5ml, 10ml, 20ml, 30ml to 50ml, which can be self-diagnosed and displayed on LCD display.
10). Alarms: Audio-visual alarms given in case of malfunction or operation error with machine stopping at the same time automatically.
11). Preset volume: Automatically saved in case of unpredictable switch-off, thus ensuring accuracy of injection volume.
12). Drug name library: As many as 200 drug names can be stored in the machine and can be checked on LCD display during operation.
Dimension | 288x130x122mm (outer shell: ABS plastic) | Power supply | 50/60Hz AC100V~240V | ||
Weight | <3.0kg | Battery | Rechargeable lithium polymer battery, 7.4V, 1600mA | ||
Selectable modes | Rate mode, Time mode, Body Weight mode | ||||
Fuse | 220V2Ax2, 12V2Ax2 | ||||
Applicable syringes | Accept all brands of standard syringes: 5ml, 10ml, 20ml, 30ml, 50ml | Electrical safety | Comply with the stipulation of GB9706.1-1995, EN60601-1 and UL60601-1 | ||
Accumulated injection volume | 0~9999.9ml | Maximum power consumption | 25VA, can run for 5h after being recharged | ||
Injection accuracy | ±2% | ||||
Feasible syringe rate range | 5ml: 0.1~100ml/h 10ml: 0.1~200ml/h 20ml: 0.1~400ml/h 30ml: 0.1~600ml/h 50ml: 0.1~1500ml/ h | Batteryrecharge | When the pump is connected to the AC power supply, turn on the power and the battery will automatically recharge (about 8-14 hours to recharge fully). | ||
Displayed Information | rate, volume limit, syringe size, pressure value, battery capacity, unit of medical dosage, bed No. AC power indicator, accumulated volume, drug name | ||||
Alarm function | OVER, NEAR, Occlusion, Low battery, Syringe disengaged, Syringe abnormal, Control abnormal, Internal malfunction | ||||
Electromagnetic compatibility | Comply with the stipulation of IEC60601-1-2 (1993 edition) EN60601-2-24 | ||||
Bolus rate | 5ml: 100ml/h, 10ml: 200ml/h, 20ml: 400ml/h, 30ml: 400~600ml/h (adjustable) 50ml: 400~1500ml/h (adjustable) | ||||
Operating conditions | Environment temperature 5ºC~45ºC, air pressure 70~106kpa, relative humidity 30%~90% | ||||
KVO rate | 0.1ml/h~5.0ml/h(selectable) | Storage | Environment temperature -15ºC~50ºC, air pressure 70~106kPa, relative humidity 30%~90% | ||
Occlusion value | 400mmHg~900mmHg | Water proof | IPX1 | ||
Time mode | Vol limit: 0.1~999.9ml Time: 0~2000 min | Classification | Class II, type BF | ||
Drug name library | 200 drug names can be stored in the machine. | Certification | CE0197 | ||
Body Weight Mode | Drug limit: 0.1~9999.9(mg/ug), Solution limit: 0.1~999.9ml, Weight: 0.1~300.0kg, Dose: 0.1~9999.9 Selectable unit: mg/kg/h, ug/kg/min | Applied standards | Accord with the stipulation of YZB/Yue0482-2004 |