Economical syringe pump 3010, CE certified
Negotiable /Unit
Min.Order:1 Unit
Guangzhou Global Healthcare Supplies Co., Ltd
Productname | Syringepump |
model | SYS-3010(LCDScreen) |
Infusionmode | Ratemode,Timemode,weightmode |
Powersupply | ACpowersupply: AC 100-240V,50/60 Hz, power consumption less than 30VA
ExternalDCpowersupply: DC 12 V
Internal battery: lithium battery 11.1 V 1500 mAh
Timeof continuous use: no less than 8 hours (for infusion at 5 mL/h with anewbattery) |
Compatiblesyringes |
All syringes of 10ml, 20ml, 30ml, 50(60)ml conform to the standard |
Infusionsettingrange | 0.1-300.0mL/h(10mLsyringe)
0.1-600.0mL/h(20mLsyringe)
0.1-900.0mL/h(30mLsyringe)
0.1-2000.0mL/h(50(60)mLsyringe)Leastincrementis 0.1 mL/h |
Totalvolumedisplay | 0.1-9999.9mL |
Accuracy | Mechanicalaccuracy:±1%Accuracyincluding syringe: ±2% |
Bolusoperation | 300.0mL/h(10mLsyringe)
600.0mL/h(20mLsyringe)
900.0mL/h(30mLsyringe)
1500.0mL/h(50(60)mLsyringe) |
KVOrate | 0.1-2.5mL/h |
Occlusionlevel | Threelevels are available:
I: 300±100 mmHg (40.0±13.3 kPa)
II: 500±100 mmHg (66.7±13.3 kPa)
III: 800±200 mmHg (106.7±26.7 kPa) |
Alarms | NearFinished,Finished,SyringeEmpty,Nearempty,Occlusion,LowBattery,BatteryEmpty,NoBattery,NoExtraPowerSupply,UnknownSyringe,SyringeInstall Error, Syringe Start Fail, Reminder Alarm |
Specialfunctions |
Repeatalarming:If there is still alarm after mute alarm sound, it will alarmagainin 2 minutes
Eventrecording:can store and playback 300 events maximum
Alarmvolumesetting:3 levels of alarm voice are available
Powersupplyswitching:WhenAC/DCpowersupplyis cut off, the
infusionautomaticallyswitch to internalbatterysupply
Barcodescanning:Input the patient information by barcode canning |
Operatingconditions | Temperature:5℃to 40℃ Humidity:15%to 95% RHPressurealtitude: 70.0kPa-106.0kPa |
Storageconditions | Temperature:-20℃to +55℃Humidity:10%to 93% RHPressure altitude:22.0kPa-107.4kPa |
Classification | ClassI, Type CF, IPX4 |
Dimensions | 320(W)× 118 (H) × 120 (D) mm |
Weight | About2 kg (including battery) |
Mainsafetystandards | IEC60601-1Medicalelectricalequipment- Part 1: General requirements forbasicsafetyandessentialperformance IEC60601-2-24Medicalelectricalequipment–Part2-24:Particularrequirementsforthesafetyofinfusionpumpsandcontrollers IEC60601-1-8Medicalelectricalequipment-- Part 1-8: Generalrequirementsforbasicsafetyandessentialperformance-- Collateralstandard: General requirements, tests and guidance for alarm systems in medicalelectricalequipmentandmedicalelectricalsystems IEC60601-1-2Medicalelectricalequipment- Part 1-2: Generalrequirementsforbasicsafety- Collateral standard: Electromagneticcompatibility requirements and tests |