Working Principle of laser tattoo removal :
Laser technology has greatly improved the ability to treat melanocytic lesions and tattoos with the rapidly pulsed Q-switch neodymium: yttrium aluminium garnet (Nd: YAG) laser. The laser treatment of pigmented lesions and tattoos are based on principle of selected photothermolysis. The QS laser Systems can successfully lighten or eradicate a variety of benign epidermal and dermal pigmented lesions and tattoos with minimal risk of untoward effects.
Laser pigment removal machine though high energy of laser transient emission, make irradiated pigment particles absorb energy expansion rupture. Most or all of epidermal pigment group split into smaller tiny particles immediately ruled out in vitro. Part of dermal pigment group fragment into body macrophage phagocytic particles that ingest and excrete through the lymphatic system, thereby eliminating pigment. Due to normal tissue on 1064nm laser absorption is very few, maintaining the cell frame complete. No scar formation conditions. Because of the laser pigment removal is no damage to normal tissues, its security guaranteed maximum customer without complications from postoperative.
Gradually the pigment becomes lighter and lighter till disappearing. Gradually the pigment becomes lighter and ligher.
I. Machine structure
The Nd:YAG Laser Tattoo Removal System is made up of light route system, power supply system, computer controlling system, cooling system, etc. The light route system is installed into the hand piece, but power supply, controlling and cooling system are installed into the machine box of power supply.
Main technical parameters:
Laser model:Q-switched Nd:YAG Laser
Laser wavelength:1064/532 nm
Pulse energy:1000mj
Pulse width:3.5ns
Repetition frequency:1, 2, 3,4,5,6 Hz
Cooling method:inner circulation water cooling
Power supply:AC110V± 10%, 50~60Hz; 230V±10%, 50~60Hz
Main physical parameters:
Dimensions:370×275×245mm3
Total weight:18kg
Each part’s name and function:
1. Emergency switch:When accident happened suddenly, press the red knob swiftly, then the machine is out of power. Turn the button in the arrow direction to spring it up and power resumes again.
2. Key switch:This is the main power supply switch. The screen displays a long horizontal line. Press the “down” button to shut down the signaling voice.
3. Simm (simmer):Pressing the knob makes system enter into the standby state.
4. Freq (frequency adjusting ) key:Set repeated frequency 1~6Hz.
5. Power (power adjusting) key:
Features
1. No harm to the hair follicle and normal skin, leaving no scar.
2. Short treating time and easy operation.
3.The high quality controlled solid-state laser complying with international standard
4. Computerized with big LCD and show in double language: English and Chinese.
5.Tiny sense of pain, anesthesia is unnecessary. in most cases, no side effect
1.With infrared light, more accurate shoting treatment area.
2.Different machine chassis option matches style of hospital, clinic, salon, beauty spa, home use, etc.
3.Water temperature and water flow alarm system ensure long time safe working.
4.Germany imported laser rod ensures higher light transmittance, with better working performance.
5.Taiwan import power supply, confirm the machine stable and strong output energy.
6. strong cooling + plug and play handle
II.Working condition
Normal working condition:
1. Temperature:5°C-30°C
2. Relative humidity:≤70%
3. Pressure:860-1060hPa
4. Power supply:AC110V± 10%, 50~60Hz; 230V±10%, 50~60Hz
Working mode:interval and continuous working mode. Best to pause for 5 minutes after each continuous outputting of 5000 pulses.
Cooling:Circulatory water cooling with distilled water
III.Power supply
power supply:AC AC110V± 10%, 50~60Hz; 230V±10%, 50~60Hz
Connection:
1. Safety fuse socket: The safety fuse is installed into the power supply socket, using safety fuse(6A/ ¢5 ×20) which is used for over loading protection.
2. Power input socket: The machine should be connected to a power supply using a power cord.
IV.Installation
a) The Nd:Yag Laser System should be installed into operating room or therapy room fulfilling the following requirements:
Temperature: 5°C-30°C,
Humidity: ≤70%
b) Power supply is installed per the above requirements. Please have qualified electrician to perform checking and installation.
c) Installing navigated spin plugs:Plug navigated spin plugs into the INTERLOCK at the back of machine trunk. Machine will stop outputting laser after pulling out the INTERLOCK.
d) Installing pedal foot switch: Plug the pedal foot switch into the F00TS at the back of machine and then screw it on tightly.
e) Screwing off the stopper on the water tank, then screwing it on tightly after adding distilled water fully.
Applications:
1. Remove all kinds of tattoo.
2. Remove pigmentation formed by pathological changes of pigment skin and mixed color, dermis spot, fleck,
black nevus, age pigment, birthmark and Nevus of Ota.
3. Remove all kinds of embroider eyebrow tattoo, embroider lip tattoo, soak lip tattoo, embroider eye line tattoo and lip line tattoo.
4.With skin rejuvenation treatment head (OPTIONAL).can fade acne scar,skin rejuvenation ,skin whitening,astringe pores ,remove black head .