9000G model 12 inch Patient Monitor Multi Parameters Patient Monitoring applicable for ICU CCU operation
USD $460 - $1,200 /Set
Min.Order:1 Set
Beijing Carejoy Technology Co., Ltd.
Patient Monitor
Feature:
Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR.
12.1" large-screen color TFT display
Built-in high-capacity battery, up to 4 hours working time
7-lead ECG waveforms display ,big fonts observational interface
Reviewable ECG waveforms, Maximum 240 hours reviewing graphic trends
Digital SpO2 technique, precise measurement for weak perfusion and finger shaking
Arrhythmia and S-T segment analysis and pacemaker detection
Protection against interference from defibrillation and electrosurgical Unit
Applicable for ICU, CCU, operation, adult, pediatrics and neonatal patient
ECG, NIBP, SPO2, TEMP, RESP, PULSE, Built-in rechargeable battery
ECG
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy: ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%
Analysis function should be started when using the above two kinds of function.
ST section
Scope: ±0.8mV
Precision : < ±0.05mV
SpO2
Detection scope: 0%-100%
Accuracy: ±1% 90%-100%
±2% 70%-89%
NIBP
Theory Electric oscillator
Cuff gassing time less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure 2.7kPa~31.3kPa (20mmHg~235mmHg)
Detection accuracy
Static pressure: ±3mmHg
Pulse rate: ±2%
RESP
Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method 0 time/minute – 100 minutes/minute
Precision of chest impedance method time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute
Temp
Single/double path
Type: Vascular/surface temperature
Scope: 20°C~50°C
Accuracy: ±0.2°C
Invasive blood pressure (selected mating)
Single/double path
Type: direct and continuous detection
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500kΩ
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage:5V (DC)
Accuracy of sensor: ±2%Isolation voltage: 4 kV
Packing listing:
No. | Standard Confirguration | Quantity
|
1 | ECG-cable is with respiration function | 1 piece
|
2 | Electrode | 1 pack
|
3 | NIBP cuff and extension tube (for adult) | 1 piece |
4 | SPO2 finger clip probe and extension cable (for adult) | 1 piece |
5 | TEMP probe (skin) | 1 piece
|
6 | Power cable | 1 piece
|
7 | Grounding Wire | 1 piece
|
8 | Operator’s Manual | 1 piece
|
|
|
|
| Optional Items
|
|
| IBP |
|
1 | Build-In Printer |
|
2 | Thermal Paper |
|
3 | ETCO2 |
|
4 | Infant Spo2 sensor |
|
5 | Battery |
|
6 | Cuff (adult/ child/ pediatric/ neonatal) |
|
7 | Trolley |
|
Our company has been a professional manufacturer & distributor for high-tech medical equipments since 2001.
We aims to provide the costeffective, reliable performance products. By collaborating with famous universities
and organizations, the company has designed and produced several types medical equipments in China market.
The quality management system of our company is ISO13485 certified.
Our products are also CE certified by MedCert Germany CE 0482.
Our company has a considerable market share in China domestic market and a growing increase in international market.
We aims to build good business relationships with more international distributors and customers sincerely.
We assures dealers and clients to continue provide products with innovative design, reliable quality, competitive prices
and rapid & effective customer service