Hot selling 12.1 inch 6 Parameters Patient Monitor NIBP SPO2 ECG TEMP RESP PR ICU CCU hospital Clinic with CE/ISO Certification
Negotiable /Set
Min.Order:1 Set
Beijing Carejoy Technology Co., Ltd.
Newest Handheld Multiparameter Touch Screen bluetooth Patient Monitor with battery
CE Approved portable Patient Monitor RPM-8000A 7 inch multi Parameter ECG, NIBP, SPO2, RESP, PR
portable 7 inch 5 Parameter Patient Monitor rpm-8000a Multi-language English Spanish Turkish
Portable Easy ECG EKG Handheld Heart Rate Monitor Sensor PRINCE 180D
PC-80B Handheld Color Screen ECG Electrocardiograph Easy Heart Monitor
patient monitor
Feature:
Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR.
12.1" large-screen color TFT display
Built-in high-capacity battery, up to 4 hours working time
7-lead ECG waveforms display ,big fonts observational interface
Reviewable ECG waveforms, Maximum 240 hours reviewing graphic trends
Digital SpO2 technique, precise measurement for weak perfusion and finger shaking
Arrhythmia and S-T segment analysis and pacemaker detection
Protection against interference from defibrillation and electrosurgical Unit
Applicable for ICU, CCU, operation, adult, pediatrics and neonatal patient
ECG, NIBP, SPO2, TEMP, RESP, PULSE, Built-in rechargeable battery
ECG
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy: ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%
Analysis function should be started when using the above two kinds of function.
ST section
Scope: ±0.8mV
Precision : < ±0.05mV
SpO2
Detection scope: 0%-100%
Accuracy: ±1% 90%-100%
±2% 70%-89%
NIBP
Theory Electric oscillator
Cuff gassing time less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure 2.7kPa~31.3kPa (20mmHg~235mmHg)
Detection accuracy
Static pressure: ±3mmHg
Pulse rate: ±2%
RESP
Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method 0 time/minute – 100 minutes/minute
Precision of chest impedance method time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute
Temp
Single/double path
Type: Vascular/surface temperature
Scope: 20°C~50°C
Accuracy: ±0.2°C
Invasive blood pressure (selected mating)
Single/double path
Type: direct and continuous detection
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500kΩ
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage:5V (DC)
Accuracy of sensor: ±2%Isolation voltage: 4 kV
Packing listing:
No. | Standard Confirguration | Quantity
|
1 | ECG-cable is with respiration function | 1 piece
|
2 | Electrode | 1 pack
|
3 | NIBP cuff and extension tube (for adult) | 1 piece |
4 | SPO2 finger clip probe and extension cable (for adult) | 1 piece |
5 | TEMP probe (skin) | 1 piece
|
6 | Power cable | 1 piece
|
7 | Grounding Wire | 1 piece
|
8 | Operator’s Manual | 1 piece
|
|
|
|
| Optional Items
|
|
| IBP |
|
1 | Build-In Printer |
|
2 | Thermal Paper |
|
3 | ETCO2 |
|
4 | Infant Spo2 sensor |
|
5 | Battery |
|
6 | Cuff (adult/ child/ pediatric/ neonatal) |
|
7 | Trolley |
|