Skin Regeneration HOT In USA!Sanhe Beauty Equipment Coherent Laser Co2 Fractional Laser Professional
USD $1 - $2 /Unit
Min.Order:1 Unit
Technology of Ultrapulse
Mainly let the original average output of the laser energy concentrated in a very short period of time then output, due to the high pulse power, short time, and more round spot, the pressure on the surface from laser heat transfer effects is low (small heat-affected zone).
10600nm Fractional low price co2 laser machine
Main Function | Wrinkle, Scar, Vascular removal, Large Pores |
Object | Beauty Med Spa /Beauty Medical Spa |
Aesthetic Center |
Detail Application( Cosmetic and Medical Application):
Cosmetic Application | Rhytides (Wrinkles) | Medical Application | Actinic keratosis (sun-damaged skin, precancerous lesions) |
Mottled dyspigmentation | Seborrheic keratosis (sun-damaged skin, precancerous lesions) | ||
Telangiectasia (Red Spots) | Sebaceous hyperplasia (yellow, shiny bumps on the face) | ||
Solar lentignes (Brown spots) | Rhinophyma (nose swelling and tissue over growth | ||
Large pores,Rough skin texture | Epidermal Melasma (Brown spots) |
Principle
1.Fractional resurfacing is a new laser treatment modality that creates numerous microscopic thermal injury zones of controlled width, depth,and density that are surrounded by a reservoir of spared epidermal and dermal tissue,allowing for rapid repair of laser-induced thermal injury. This unique modality, if implemented with proper laser- delivery systems, enables high-energy treatments while minimizing risks.
2.This machine use the RF Tube manufacturerd by Coherent America,the frequency can reach more than
5000HZ,the high speed can work more efficiecnt and effectively,it is very good for the ultra pulse incision for the precise surgey,no blood,the treatment area is very clear,andless down time.
Import Coherent RF Tube Laser generator
Two Treatment Heads(100mm and 50mm)
Scanner Head: 100mm diameter (Scanning Size: Maximum 20*20mm)
Cutting Surgery Head: 100mm diameter
Scanner Head: 50mm diameter (Scanning Size: Maximum 15*15mm)
Cutting Surgery Head: 50mm diameter
The Advantage of the RF Tube Fractional laser
1.RF Laser generator is more stable than traditional glass tube ,it is dot need service
2.With the RF laser Tube,the scanning depth can reach the derma layer,to accelerate the collagen regrowth
3.RF Laser Tube makes the scanning dot much thinner and less harm
4.The Laser Tube frequency can reach more than 5000HZ,high speed scanner can get better treatment effect
5.The high frequency of the RF Tube make the machine reach the ultra pulse mode ,whole machine can use Fractional,CW,Pulse,Ultra Pulse,one machine can been used widely in different surgery
6.Special designed energy self-inspected and energy replenishment system,improving the stability and effect
7.Multi safety protection,water ,electric,remote interlock warning alarm
8.Laser anti-leak designing,confirm the operator and client safety
9.Whole low voltage system,no electric danger and no electric radiation
Parameters:
Laser source | RF Laser Tube |
(Manufactured by Coherent America) | |
Working Mode | Fractional Mode |
Continuous Wave Mode (CW) | |
Pulse Mode (single and repeated) | |
Ultra Pulse Mode | |
Laser Wavelength | 10600nm |
Power of laser generator | Max 60W |
Output Power | 1-30W |
Focus Diameter | ≤0.1-1.2 mm |
Treatment Depth | Max 2mm |
Aiming Beam | Red Diode laser (650nm,≤5mW) |
Delivery System | 7-Articulation Joint Spring Arm |
Scanning Area | Max 20×20mm |
Scanning shape | Ellipse, Rectangular, Triangular, Line, Square, Hexagon |
Scanning mode | Sequence Mode |
Middle split Mode | |
Random Mode | |
Smoke Exhausting System | Built-in air blow |
Cooling system | Air Cooling |
Environmental temperature | 5°C~40°C |
Relative Humidity | ≤80% |
Power Supply | ~220V±22V,50Hz±1Hz |
Dimension | 450mm×550mm×1400mm |
Weight | 40kg |
Effect:
CO2 laser system
The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis.
The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate.
Theory - co2 fractional laser
Application:
1. Application Range of Fractional treatment handpiece
a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.
b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;
c. Reconstruction of photoaging skin.
2. Application Range of Incision Handpiece
a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery
b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc