CO2 Fractional Laser Beauty 10.6um Equipment Birth Mark Removal
USD $1 - $10,000 /Piece
Min.Order:1 Piece
Beijing Goldenlaser Development Co., Ltd.
Application:
1. Application Range of Fractional treatment handpiece
a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.
b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;
c. Reconstruction of photoaging skin.
OUR VALUE MESSAGE IS “QUALITY IS OUR CULTURE”
“WITH US YOUR MONEY IN SAFE YOUR BUSINESS IN SAFE”
1. 100% after-sales quality assurance, Support Many payment method;
2. All other specifications of beauty equipment are available according to your requirement(OEM&ODM)! Factory price you will get from NUBWAY
3. We can provide professional operation training.
4. Nd yag laser, cryolipolysis machine, hair laser machine etc with CE certifications and strong supply ability.
2. Application Range of Incision Handpiece
a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery
b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc
UltraPulse CO2 Fractional Laser
Laser Type | co2 fractional laser |
Wavelength | 10600nm |
Beam Delivery | 7-joint arm |
Maximum Output Power | 35W/25W/15W (optional) |
Optical Beam Quality | TEM |
Spot Size | 0.12-1.25mm (Adjustable) |
Power of the Aiming Beam | <5mW |
Aiming Beam 635nm | 635nm |
Scanning Mode | Randomized Scanning |
Laser Operating Mode l | UltraPulse, CW, Fractiona |
Cooling | Air Cooling |
Pulse Energy | 10mj~200mj (every stepping:2mj) |
Spot Pattern | Triangle/Square/Rectangle/Rhombus |
Pulse Interval | 1ms~100ms (every stepping:1mj) |
Scan Area | 10mmx10mm,20mmx20mm,30mmx30mm |
Working Mode | Continuous operation |
Spot Density
| 36 spots/cm² , 144 spots/cm², 576spots/cm² with intermittent loading |
Power Supply | AC 220V 50Hz/AC 110V 60Hz |
Gross Weight | 88KGS |
Dimensions(before packaged) | 650mmx340mmx760mm |
Dimensions (after packaged) | 760mmx455mmx975mm |
CO2 laser system
The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis.
The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate.
Treatment Theory
Fractional laser light penetrates the skin with tiny thermal channels through the random scanning, creating an ablative and thermal effecton only channels (a micro-injury) without damaging the surrounding tissue. The tissue surrounding the micro-injury sites (about 15-20% of the treatment area) starts the process of healing. As collagen remodels, skin tightened, scars improved and pigmented lesions removed.
Application
1. Application Range of Fractional treatment handpiece
a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.
b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;
c. Reconstruction of photoaging skin.
2. Application Range of Incision Handpiece
a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery
b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc
GLO60 Advantages
l Three modes of laser energy output are selective: UltraPulse, CW and Fractional modes
l Adopt COHERENT RF-excited laser system enables the output quality more stable, more uniform, more consistent, (compared to ordinary CO2 laser installed with glass tubes)
l Healing zone volume is adjustable, namely the volume of spots is adjustable in a certain healing zone. Therapists could adjust the spot density upon skin type, lesion parts and effectiveness requirement of different patients
l Various spot volumes are suitable for different area of the body which maximally avoid the side-effect that result from the overlap of the spot, reduce the pain during the treatment, satisfy different therapiests’ unique request.
l 10.4” TFT touch LCD, rotated 360° gives you a luxury enjoyment;
l Reserved entry access for laser room ensures a safe treatment
l Comparing with existing traditional CO2 Sealed Glass Laser, RF excited CO2 lasts nearly permanently, therefore it deserves a higher initial cost which will be offset by a much lower total of ownership.
Technology of Ultrapulse
Mainly let the original average output of the laser energy concentrated in a very short period of time then output, due to the high pulse power, short time, and more round spot, the pressure on the surface from laser heat transfer effects is low (small heat-affected zone).